欢迎访问ic37.com |
会员登录 免费注册
发布采购

29-7402-500-FL 参数 Datasheet PDF下载

29-7402-500-FL图片预览
型号: 29-7402-500-FL
PDF下载: 下载PDF文件 查看货源
内容描述: 高达500 mW的光纤布拉格光栅稳定980nm泵浦模块 [Up to 500 mW Fiber Bragg Grating Stabilized 980 nm Pump Modules]
分类和应用: 光纤
文件页数/大小: 6 页 / 261 K
品牌: JDSU [ JDSU ]
 浏览型号29-7402-500-FL的Datasheet PDF文件第1页浏览型号29-7402-500-FL的Datasheet PDF文件第2页浏览型号29-7402-500-FL的Datasheet PDF文件第4页浏览型号29-7402-500-FL的Datasheet PDF文件第5页浏览型号29-7402-500-FL的Datasheet PDF文件第6页  
2900-FL SERIES  
Table 1: Absolute Maximum Ratings  
Parameter  
Symbol  
Test Condition  
Minimum  
Maximum  
Operating case temperature  
Storage temperature  
LD submount temperature  
LD reverse voltage  
LD forward current  
LD reverse current  
PD reverse voltage  
PD forward current  
Electrostatic discharge (ESD)  
TEC current  
TEC voltage  
Axial pull force  
Side pull force  
Fiber bend radius  
Relative humidity  
Lead soldering time  
Top  
Tstg  
TLD  
Vr  
-
-20 °C  
-40 °C  
0 °C  
-
-
-
-
-
-
-
-
-
75 °C  
85 °C  
50 °C  
2.5 V  
1100 mA  
10 µA  
20 V  
10 mA  
1000 V  
4.0 A  
4.5 V  
5 N  
2000 hours  
-
-
If_max  
48 hours maximum  
-
-
-
VPD  
IPD  
VESD  
ITEC  
VTEC  
C = 100 pF, R = 1.5 Ω, human body model  
-
-
3 x 10 seconds  
3 x 10 seconds  
-
40 °C  
300 °C  
-
2.5 N  
-
95%  
16 mm  
5%  
-
RH  
10 seconds  
Note: Absolute maximum ratings are the maximum stresses that may be applied to the pump module for short periods of time without causing damage. Stresses in excess of the absolute maximum ratings  
can permanently damage the device. Exposure to absolute maximum ratings for extended periods, or exposure to more than one absolute maximum rating simultaneously may adversely affect device  
reliability.  
Table 2: Operating Parameters  
(BOL3Tcase = 0 to 75 °C3TLD = 25 °C3 -50 dB reflection3 unless noted otherwise)  
Product  
Code  
Maximum  
Operating  
Power  
Maximum  
Operating  
Current  
Minimum  
Kink-Free  
Power  
Kink-Free  
Current  
Imax (mA)3  
Maximum2  
Pop (mW)1,3  
Iop (mA)  
Pmax (mW)2  
Maximum1  
29-xxxx-310-FL  
29-xxxx-320-FL  
29-xxxx-330-FL  
29-xxxx-340-FL  
29-xxxx-350-FL  
29-xxxx-360-FL  
29-xxxx-380-FL  
29-xxxx-400-FL  
29-xxxx-420-FL  
29-xxxx-440-FL  
29-xxxx-460-FL  
29-xxxx-480-FL  
29-xxxx-500-FL  
280  
290  
300  
310  
315  
325  
340  
360  
380  
400  
410  
430  
450  
560  
590  
630  
640  
650  
660  
680  
720  
760  
805  
840  
875  
900  
310  
320  
330  
340  
350  
360  
380  
400  
420  
440  
460  
480  
500  
640  
670  
700  
700  
700  
700  
760  
805  
855  
910  
950  
985  
1000  
1. The maximum operating power (Pop) will be achieved at a device-specific maximum operating current (Iop). The individual value of Iop is noted on the hardcopy data sheet shipped with the device.  
All values of Iop are limited by the maximum value listed in Table 2.  
2. The module is kink-free up to a minimum kink-free power (Pmax) that the module will achieve at a device-specific kink-free current (Imax). The individual value of Imax is noted on the hardcopy data sheet  
shipped with the device. All values of Imax are limited by the maximum value listed in Table 2.  
3. The pump laser shall never be operated at a power higher than the Pop throughout its lifetime. At beginning of life (BOL), the operating current shall never be higher than the device-specific Iop that is  
noted on the hardcopy data sheet shipped with the device. At end of life (EOL), the operating current shall never be higher than the device-specific Imax that is noted on the hardcopy data sheet shipped  
with the device.