29-7402-480-FL 参数 Datasheet PDF下载

29-7402-480-FL图片预览
型号: 29-7402-480-FL
PDF下载: 下载PDF文件 查看货源
内容描述: 高达500 mW的光纤布拉格光栅稳定980nm泵浦模块 [Up to 500 mW Fiber Bragg Grating Stabilized 980 nm Pump Modules]
分类和应用: 光纤监视器通信
文件页数/大小: 6 页 / 261 K
品牌: JDSU [ JDS UNIPHASE CORPORATION ]
 浏览型号29-7402-480-FL的Datasheet PDF文件第1页浏览型号29-7402-480-FL的Datasheet PDF文件第2页浏览型号29-7402-480-FL的Datasheet PDF文件第3页浏览型号29-7402-480-FL的Datasheet PDF文件第5页浏览型号29-7402-480-FL的Datasheet PDF文件第6页  
2900-FL SERIES
4
Table 3: Available Peak Wavelength Selection
(T
amb
= 25±3 °C, 50 mW < P < P
op
)
Product Code
29-7402-xxx-FL
29-7552-xxx-FL
29-7602-xxx-FL
29-7702-xxx-FL
Minimum Peak Wavelength
973.5 nm
974.5 nm
975.0 nm
976.0 nm
Maximum Peak Wavelength
975.0 nm
976.5 nm
977.0 nm
978.0 nm
Table 4: Electro-Optical Performance
(BOL,T
case
= 0 to 75 °C,T
LD
= 25 °C, -50 dB reflection, unless noted otherwise)
Parameter
Threshold current
Forward voltage
Spectral width
Peak wavelength tuning
Side-mode suppression ratio
Relative optical power stability
Symbol
I
th
V
f
Δλ
RMS
Δλ
P
/ΔΤ
amb
SMSR
Test Condition
-
I
f
= I
op
50 mW < P < P
op
50 mW < P < P
op
50 mW < P < P
op
Peak-to-peak, T = 10 min,
50 kHz sampling, T
case
= 25 °C
20 mW < P < P
op
12 mW < P < 20 mW
3.5 mW < P < 12 mW
20 mW < P < P
op
1
20 mW < P < P
op
2
20 mW < P < P
op
T
case
= 75 °C
T
case
= 75 °C
-
-
T
case
= 75 °C, BOL
T
case
= 75 °C, EOL
Minimum
-
-
-
-
15 dB
Maximum
30 mA
2.5 V
2.0 nm
0.02 nm/°C
-
Tracking error
Tracking ratio
Monitor diode responsivity
TEC current
TEC voltage
Thermistor resistance
Thermistor constant
Module power consumption
TE
TR
Resp
BF
I
TEC
V
TEC
R
th
B
-
-
-
-8%
0.90
2 µA/mW
-
-
9.5 kΩ
3600 K
-
-
4%
10%
25%
8%
1.10
10 µA/mW
1.9 A
2.5 V
10.5 kΩ
4200 K
8.2 W
9.5 W
1. The tracking error is defined as the normalized change of output power relative to the operating power over case temperature range (0 °C to 75 °C), at constant back-face monitor current corresponding
to the operating power at 25 °C.
2. The tracking ratio is a measure of the front-to-back tracking when the output power is varied. On a plot of optical power versus back-face photocurrent, a straight line is drawn between the minimum
power (20 mW) and the operating power (P
op
) points. The tracking ratio is defined as the ratio between measured optical power (shown as data points on the plot) to the value derived from the straight line.