2900-FL SERIES
3
Table 1: Absolute Maximum Ratings
Parameter
Operating case temperature
Storage temperature
LD submount temperature
LD reverse voltage
LD forward current
LD reverse current
PD reverse voltage
PD forward current
Electrostatic discharge (ESD)
TEC current
TEC voltage
Axial pull force
Side pull force
Fiber bend radius
Relative humidity
Lead soldering time
Symbol
T
op
T
stg
T
LD
V
r
I
f_max
V
PD
I
PD
V
ESD
I
TEC
V
TEC
Test Condition
-
2000 hours
-
-
48 hours maximum
-
-
-
C = 100 pF, R = 1.5
Ω,
human body model
-
-
3 x 10 seconds
3 x 10 seconds
-
40 °C
300 °C
Minimum
-20 °C
-40 °C
0 °C
-
-
-
-
-
-
-
-
-
-
16 mm
5%
-
Maximum
75 °C
85 °C
50 °C
2.5 V
1100 mA
10 µA
20 V
10 mA
1000 V
4.0 A
4.5 V
5N
2.5 N
-
95%
10 seconds
R
H
Note: Absolute maximum ratings are the maximum stresses that may be applied to the pump module for short periods of time without causing damage. Stresses in excess of the absolute maximum ratings
can permanently damage the device. Exposure to absolute maximum ratings for extended periods, or exposure to more than one absolute maximum rating simultaneously may adversely affect device
reliability.
Table 2: Operating Parameters
(BOL, T
case
= 0 to 75 °C, T
LD
= 25 °C, -50 dB reflection, unless noted otherwise)
Product
Code
Maximum
Operating
Power
P
op
(mW)
1,3
Maximum
Operating
Current
I
op
(mA)
Maximum
1
560
590
630
640
650
660
680
720
760
805
840
875
900
Minimum
Kink-Free
Power
P
max
(mW)
2
Kink-Free
Current
I
max
(mA)
3
Maximum
2
29-xxxx-310-FL
29-xxxx-320-FL
29-xxxx-330-FL
29-xxxx-340-FL
29-xxxx-350-FL
29-xxxx-360-FL
29-xxxx-380-FL
29-xxxx-400-FL
29-xxxx-420-FL
29-xxxx-440-FL
29-xxxx-460-FL
29-xxxx-480-FL
29-xxxx-500-FL
280
290
300
310
315
325
340
360
380
400
410
430
450
310
320
330
340
350
360
380
400
420
440
460
480
500
640
670
700
700
700
700
760
805
855
910
950
985
1000
1. The maximum operating power (P
op
) will be achieved at a device-specific maximum operating current (I
op
). The individual value of I
op
is noted on the hardcopy data sheet shipped with the device.
All values of I
op
are limited by the maximum value listed in Table 2.
2. The module is kink-free up to a minimum kink-free power (P
max
) that the module will achieve at a device-specific kink-free current (I
max
). The individual value of I
max
is noted on the hardcopy data sheet
shipped with the device. All values of I
max
are limited by the maximum value listed in Table 2.
3. The pump laser shall never be operated at a power higher than the P
op
throughout its lifetime. At beginning of life (BOL), the operating current shall never be higher than the device-specific I
op
that is
noted on the hardcopy data sheet shipped with the device. At end of life (EOL), the operating current shall never be higher than the device-specific I
max
that is noted on the hardcopy data sheet shipped
with the device.