2600 SERIES
3
Table 1: Absolute Maximum Ratings
Parameter
Operating case temperature
Storage temperature
LD submount temperature
LD reverse voltage
LD forward current
LD current transient
LD reverse current
PD reverse voltage
PD forward current
Electrostatic discharge (ESD)
TEC current
TEC voltage
Axial pull force
Side pull force
Fiber bend radius
Relative humidity
Lead soldering time
Symbol
T
op
T
stg
T
LD
V
r
Test Conditions
-
2000 hours
-
-
-
1 µs maximum
-
-
-
C = 100 pF, R = 1.5
Ω,
human body model
-
-
3 x 10 seconds
3 x 10 seconds
-
40 °C
260 °C
Minimum
-5 °C
-40 °C
0 °C
-
-
-
-
-
-
-
-
-
-
-
16 mm
5%
-
Maximum
75 °C
85 °C
50 °C
2V
650 mA
950 mA
10 µA
20 V
10 mA
1000 V
2.5 A
4.0 V
5N
2.5 N
-
95%
10 seconds
V
PD
I
PD
V
ESD
I
TEC
V
TEC
R
H
Note: Absolute maximum ratings are the maximum stresses that may be applied to the pump module for short periods of time without causing damage. Stresses in excess of the absolute maximum ratings can
permanently damage the device. Exposure to absolute maximum ratings for extended periods, or exposure to more than one absolute maximum rating simultaneously may adversely affect device reliability.
Table 2: Operating Parameters
(BOL, T
case
= 0 to 75 °C, T
LD
= 25 °C, -50 dB reflection, unless noted otherwise)
Product
Code
1
Maximum
Operating
Power
P
op
(mW)
2,3
Maximum
Operating
Current
I
op
(mA)
Maximum
2
240
240
260
270
280
300
320
340
340
Minimum
Kink-Free
Power
P
max
(mW)
4
Kink-Free
Current
I
max
(mA)
3
Maximum
4
26-xxxx-100
26-xxxx-110
26-xxxx-120
26-xxxx-130
26-xxxx-140
26-xxxx-150
26-xxxx-160
26-xxxx-170
26-xxxx-180
90
100
110
120
125
135
145
155
160
100
110
120
130
140
150
160
170
180
260
260
270
290
310
330
350
370
380
1. The 27-xxxx-xxx may be substituted for this part series. All 26-xxxx-xxx end product specifications will remain as published; there is no change to part numbers, product testing, quality or reliability.
Traceability is accomplished through product serial number.
2. The maximum operating power P
op
will be achieved at a device-specific current, the maximum operating current I
op
. The individual value of I
op
is noted on the hardcopy data sheet shipped with the device.
All values of I
op
are limited by the maximum value listed in Table 2.
3. The pump laser shall never be operated at a power higher than the maximum operating power P
op
throughout its lifetime. At Begin of Life (BOL), the operating current shall never be higher than the
device-specific maximum operating current I
op
that is noted on the hardcopy data sheet shipped with the device. At End of Life (EOL), the operating current shall never be higher than the device-specific
kink-free current I
max
that is noted on the hardcopy data sheet shipped with the device.
4. The module is kink-free (at least) up to a minimum kink-free power P
max
that the module will achieve at a device-specific current, the kink-free current I
max
. The individual value of I
max
is noted on the
hardcopy data sheet shipped with the device. All values of I
max
are limited by the maximum value listed in Table 2.