Technical Data (20°C)
SERIE 7 - Ø 18 mm - Low, medium and high pressure ranges
SPECIFICATIONS
RANGE IDENTIFICATION :
RATED RANGE : (R.R.)
ED71
FA FB DB FE DE DG CG DL CL CQ CR Cꢀ CZ
(bar)
(≅ psi)
(bar)
2
4
6
10 16 25 40 60 100 160 250 400 600
30 60 90 150 250 350 600 900 500 2500 4000 6000
12 20 32 50 80 120 200 320 500 800 800
12 18 30 48 75 120 180 300 480 600 1000
1
-
Max. admissible pressure, without derating of specs :
Burst pressure : ≥
OUTPUT SIGNAL AT R.R. : (1)
5
7
8
(bar)
-
30%
(mV)
20 20 20 20 22 22 25 22 25 27 25 30 25
GLOBAL ERROR :
(non linearity + hysteresis + repeatability)
(% R.R.)
≤ 0.4
≤ 0.6
EXCITATION
Nominal :
Maximum :
(Volt)
(Volt)
10
20
BRIDGE IMPEDANCE
Input :
Output :
(kOhm)
(kOhm)
Closed bridge : ≥ 6
15 30%
TEMPERATURE LIMITS
Operating :
Compensated :
(°C)
(°C)
-55 to +125
n.a.
THERMAL DRIFTS
Zero :
Output signal :
(µV / °C)
(% / °C)
≤
30
0.01
LONGTERM ZERO DRIFT :
INITIAL ZERO UNBALANCE (1)
DIMENSIONS
(% R.R. / year)
(mV)
≤ 0.2 (non cumulative)
≤
See fig. 3
2
(1) ꢀnder nominal excitation voltage : 10 V
Dimensions
Tightening force loading
area (ø 40)
e
Figure 1
Range identification
Model
identification
e : mm
1 ꢀ
RB
RC
RD
RE
RG
5.30
5.35
5.40
5.45
5.55
Connecting pads
2.54 mm pitch
Option : ZITEX humidity protector
(gauge pressure measurement only)
Ventilation hole (gauge
pressure measurement)
Series 1
e
Tightening force
loading area (ø 30)
Figure 2
Range identification
Model
Identification
e : mm
1 ꢀ
MB
6.30
6.35
6.45
6.625
6.85
7.30
8.05
8.55
Connecting pads
2.54 mm pitch
MC LC
LE
LI
LL
LR HR ER
EZ
Option : ZITEX humidity
protector (gauge pressure
measurement only)
Ventilation hole (gauge
pressure measurement)
EP
Series 2
Figure 3
Model
Identification
e : mm
1 ꢀ
Tightening force
loading area (ø 15)
FA
FB DB
FE DE
DG CG
DL CL
CQ
6.25
6.30
6.45
6.55
6.85
7.05
7.30
7.65
7.82
Connecting pads
2.54 mm pitch
1 Excit.
2 Signal
3 Signal
4 Excit
Option : ZITEX humidity protector
(gauge pressure measurement only)
CR
Ventilation hole (gauge
pressure measurement)
Series 7
Cꢀ
CZ
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A12.20
Page 4