Bridge Amplifier, Selectable Configuration
DABx MP4M
Features
• S/G Bridge amplifier
• Selectable bridge configuration
• Limit switches with switching output
• Peak value
• Double-line display
• Voltage and current output
• Digital signal path
Electrical Data
Output signal
Resolution
Measuring accuracy
Supply voltage range
Current consumption
Bridge excitation
Bridge completion
resistors
Zero
reset active
Reset input
galvanically separated
Taring range
Reset pulse
Holding time
Reset/operate offset
Scanning rate
Frequency range (3 dB)
Display
refresh rate
Switching hysteresis
limit switches
Max. load
limit switches
Signal polarity
DABU
±10 V calibrated
load > 10 kΩ
< 0,035% FS
< 0,15% v.E.
DABI
4 - 20 mA
shunt < 500
Ω
< 0,07% FS
Mechanical Data
Control connection
Sensor connection
Shield connection
Enclosure material
13 pin terminal block
13 pin terminal block
2 pin terminal block
aluminum/plastic
15 - 33 VDC
< 120 mA
5 VDC
350
Ω
Environmental Conditions
Operating temp. range
0...+65 °C
-20...+80 °C
IP 40
Storage temperature
Protection class
< ±10 mV
< ±10
µA
active 5 - 33 VDC
inactive <1 VDC
±6 mV/V
< 1 ms
< 5 ms
< ±10 mV
> 1 ms
300 Hz
2/sec
< 0,5% FS
max. 50 mA
selectable
< ±15
µA
Order Code
DAB
MP4M-FC-
Gain
0.50
=0,50 mV/V= 0-10 V resp. 4-20 mA
0.75
=0,75 mV/V= 0-10 V resp. 4-20 mA
1.00
=1,00 mV/V= 0-10 V resp. 4-20 mA
1.25
=1,25 mV/V= 0-10 V resp. 4-20 mA
2.00
=2,00 mV/V= 0-10 V resp. 4-20 mA
Output signal
U
Voltage output ±10 V
I
Current output 4 - 20 mA
Delivery Contents
• Clamping clip for ground connection
6.12
www.baumer.com