BMMV 42
MAGRES
SSI
dimensions (C6)
-5
ø 6 h8
M3 x 6
3 x 120°
dimensions (C0)
-5
ø 10 h8
12
9
M3 x 6
3 x 120°
16
2,2
1
12
2
46
8,5
33
42
28
0
-0,025
2,2
1
15
2
46
8,5
33
42
28
16
0
-0,025
-N
M3 x 6
3 x 120°
-N
12
M3 x 6
3 x 120°
ø 6 h8
3
28
-0,025
33
42
0
ø 10 h8
15
9
2,2
1
12
2
46
28
-0,025
33
42
0
2,2
1
15
2
46
Note
Mounting drawings see end of chapter.
read out of position values
n clock
t1
clock
T
t3
SSI data output and clock input
see page 2.03 chapter absolute single-turn encoders
data
t2
Bit n Bit n-1
Bit 3
15
Bit 2 Bit 1
pulse times:
T = 1 µs to 10 µs / t1 = 0,5 µs to 5 µs
t2 < 0,2 µs / t3 > 12 µs to 25 µs
assignment cable
cable color
brown
white
grey
pink
green
yellow
blue
red
screen
cable data
signal
+V
S
0V
data+
data-
clock+
clock-
zero
d.u.
description
voltage supply
voltage supply
data line
data line
clock input
clock input
zero setting input
do not use
housing
8 x 0,14 mm
2
assignment connector M12
for connection reference
-N
pin
5
6
7
1
8
2
4
3
signal
0V
+Vs
clock+
clock-
data+
data-
zero
d.u.
description
voltage supply
voltage supply
clock input
clock input
data line
data line
zero setting input
do not use
1
2
3
4
5
6
7
8
www.baumerelectric.com