 浏览型号BMF3P.24P4096-C0-K的Datasheet PDF文件第1页浏览型号BMF3P.24P4096-C0-K的Datasheet PDF文件第2页浏览型号BMF3P.24P4096-C0-K的Datasheet PDF文件第4页  
Programmable
switching cam encoder
BME/BMF parallel
assignment
Designation parallel
connector signal
37-pin
cable
color
signals parallel interface
16 cam outputs
Up to 250 cams can be programmed to
these 16 outputs. For each data line, we
recommend Pull-DOWN resistors for PNP and
Pull-UP resistors for NPN, both with 4.7 kΩ
values.
17 - 19
not used
20 - 24
factory diagnostic outputs
D19 - D23
These outputs may be assigned, at choice,
to the functions preset 1, preset 2,
speed monitoring or diagnosis.
27 ZERO
Reset input for setting a zero at any point
within the programmed encoder resolu-
tion. The zero setting is triggered by a HIGH
pulse imperatively after the sense of direction
has been chosen (F/R). Assign to GND for
maximum interference immunity after
zero setting. Pulse duration
100 ms.
28 ENABLE
If this input is at LOW level, the output
drivers will be activated. If HIGH potential is
applied (or if open-circuited), the output
drivers will turn to the HIGH-resistance
state (Tristate).
29 STORE
When a LOW level is applied, the data of
the absolute encoder is temporarily stored.
If this input is connected to HIGH potential
or if it remain closed, the current position
data of the absolute encoder is switched
through to the output drivers. This line
must be used to ensure data readout in
binary code.
30 F/R
Input for counting up and down. If open-
circuited, it is set to HIGH. HIGH means
increasing output data if shaft rotates clock-
wise when looking at the flange. LOW means
increasing values if shaft rotates counter-
clockwise when looking at the flange.
34 GND-Sense This contact is connected internally to GND
and assists, together with VS-sense, to
measure the supply voltage at the encoder via
the follower electronic.
35 +V
S
-Sense This contact is connected internally to +Vs.
If the sensor line is not to be used, this contact
must be isolated (danger of short circuit).
36 +Vs
Supply voltage of encoder.
37 GND
Ground contact of encoder with reference
to +Vs.
1 - 16
S0 - S15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
S0
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
-
-
-
D19
D20
D21
D22
D23
-
-
ZERO
ENABLE
STORE
F/R
-
-
-
GND
Sense
+V
Sense
+V
S
GND
WH
BN
GN
YE
GY
PK
BK
VT
GY/PK
RD/BU
WH/GN
BN/GN
WH/YE
YE/BN
WH/GY
GY/BN
WH/PK
PK/BN
WH/BK
BN/BK
GY/GN
YE/GY
PK/GN
YE/PK
-
-
YE/BU
BN/BU
BN/RD
GN/BU
-
-
-
WH/BU
WH/RD
RD
BU
white
brown
green
yellow
grey
pink
black
violet
grey/pink
red/blue
white/green
brown/green
white/yellow
yellow/brown
white/grey
grey/brown
white/pink
pink/brown
white/black
brown/black
grey/green
yellow/grey
pink/green
yellow/pink
-
-
yellow/blue
brown/blue
brown/red
green/blue
-
-
-
white/blue
white/red
red
blue
Screen: In the case of encoders with cable
output, the screen is connected to the housing internally.
www.baumerelectric.com