 浏览型号MDM-25SBSP-A172的Datasheet PDF文件第79页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第80页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第81页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第82页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第83页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第85页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第86页浏览型号MDM-25SBSP-A172的Datasheet PDF文件第87页  
Product Safety Information  
This note must be read in conjunction with the product data sheet/catalog. failure to observe  
the advice in this information sheet and the operating conditions specified in the product data  
sheet/ catalog could result in hazardous situations.  
1. MATERIAL CONTENT AND PHYSICAL FORM  
5. APPLICATION  
(a) Electrical connectors do not usually contain hazardous materials.  
They contain conducting and non-conducting materials and can be  
divided into two groups:  
Printed circuit types and low cost audio types which employ all plastic  
insulators and casings.  
Connectors with exposed contacts should not be selected for use on  
the current supply side of an electrical circuit, because an electric  
shock could result from touching exposed contacts on an unmated  
connector. Voltages in excess of 30 V ac or 42.5 V dc are potentially  
hazardous and care should be taken to ensure that such voltages  
cannot be transmitted in any way to exposed metal parts of the  
connector body. The connector and wiring should be checked, before  
making live, to have no damage to metal parts or insulators, no  
solder blobs, loose strands, conducting lubricants, swarf or any other  
undesired conducting particles. Circuit resistance and continuity check  
should be made to make certain that there are no high resistance  
joints or spurious conducting paths. Always use the correct application  
tools as specified in the Data Sheet/Catalog. Do not permit untrained  
personnel to wire, assemble or tamper with connectors. For operation  
voltage please see appropriate national regulations.  
(b) Rugged, Fire Barrier and High Reliability types with metal casings  
and either natural rubber, synthetic rubber, plastic or glass insulating  
materials. Contact materials vary with type of connector and also  
application and are usually manufactured from either: Copper, copper  
alloys, nickel, alumel, chromel or steel. In special applications, other  
alloys may be specified.  
2. FIRE CHARACTERISTICS AND ELECTRIC  
SHOCK HAZARD  
There is no fire hazard when the connector is correctly wired and  
used within the specified parameters.  
IMPORTANT GENERAL INFORMATION  
Incorrect wiring or assembly of the connector or careless use of  
metal tools or conductive fluids, or transit damage to any of the  
component parts may cause electric shock or burns. Live circuits must  
not be broken by separating mated connectors as this may cause  
arcing, ionization and burning. Heat dissipation is greater at maximum  
resistance in a circuit. Hot spots may occur when resistance is raised  
locally by damage, e.g. cracked or deformed contacts, broken strands  
of wire. Local over- heating may also result from the use of the  
incorrect application tools or from poor quality soldering or slack screw  
terminals. Overheating may occur if the ratings in the product Data  
Sheet/Catalog are exceeded and can cause breakdown of insulation  
and hence electric shock. If heating is allowed to continue it intensifies  
by further increasing the local resistance through loss of temper of  
spring contacts, formation of oxide film on contacts and wires and  
leakage currents through carbonization of insulation and tracking  
paths. Fire can then result in the presence of combustible materials  
and this may release noxious fumes. Overheating may not be visually  
apparent. Burns may result from touching overheated components.  
(i) Air and creepage paths/operating voltage. The admissible operating  
voltages depend on the individual applications and the valid national  
and other applicable safe- ty regulations.  
For this reason the air and creepage path data are only reference  
values. Observe reduction of air and creepage paths due to PC board  
and/or harnessing.  
(ii) Temperature. All information given are temperature limits.  
The operation temperature depends on the individual application.  
(iii) Other important information. Cannon continuously endeavors to  
improve their products. Therefore, Cannon products may deviate from  
the description, technical data and shape as shown in this catalog and  
data sheets.  
ITT Cannon is a business unit of ITT Cannon Inc., which manufactures  
the highest quality products available in the marketplace; however  
these products are intended to be used in accordance with the  
specifications in this publication. Any use or application that deviates  
from the stated operating specifications is not recommended and may  
be unsafe. No information and data contained in this publication shall  
be construed to create any liability on the part of Cannon. Any new  
issue of this publication shall automatically invalidate and supersede  
any and all previous issues  
3. HANDLING  
Care must be taken to avoid damage to any component parts of  
electrical connectors during installation and use. Although there are  
normally no sharp edges, care must be taken when handling certain  
components to avoid injury to fingers. Electrical connectors may  
be damaged in transit to the customers, and damage may result in  
creation of hazards. Products should therefore be examined prior to  
installation/use and rejected if found to be damaged.  
All data subject to change without notice.  
4. DISPOSAL  
Incineration of certain materials may release noxious or even  
toxic fumes.  