欢迎访问ic37.com |
会员登录 免费注册
发布采购

M39012/59-3026 参数 Datasheet PDF下载

M39012/59-3026图片预览
型号: M39012/59-3026
PDF下载: 下载PDF文件 查看货源
内容描述: 射频同轴连接器 [RF Coaxial Connectors]
分类和应用: 连接器射频
文件页数/大小: 42 页 / 490 K
品牌: ITT [ ITT Cannon ]
 浏览型号M39012/59-3026的Datasheet PDF文件第15页浏览型号M39012/59-3026的Datasheet PDF文件第16页浏览型号M39012/59-3026的Datasheet PDF文件第17页浏览型号M39012/59-3026的Datasheet PDF文件第18页浏览型号M39012/59-3026的Datasheet PDF文件第20页浏览型号M39012/59-3026的Datasheet PDF文件第21页浏览型号M39012/59-3026的Datasheet PDF文件第22页浏览型号M39012/59-3026的Datasheet PDF文件第23页  
RF Coaxial Connectors  
Assembly Instructions  
AI-472 & BAI-015  
SMB & SMS Right Angle Connectors, Crimp Type for Braided Cable  
CRIMP FERRULE  
CAP  
BODY  
1. Trim cable to dimensions shown taking care not to nick braid or center conductor. Tin center  
conductor (DO NOT OVER TIN) then slip crimp ferrule (and tubing with SMS) over cable with  
inspection hole toward trimmed end.  
Assembly Instruction No.  
BAI-015  
A
B
C
10,00 (.393)  
11,10 (.437)  
4,00 (.157)  
4,37 (.172)  
1,50 (.059)  
0,79 (.031)  
AI-472  
2. Insert trimmed cable into back end of body. The tubular body extension will slide under the braid  
with the rear portion of extension fitting under the jacket as shown. The center conductor will  
extend into slot in contact.  
NOTE: On smaller diameter cables, two longitudinal slits in the jacket, 180° apart, may be cut to  
ease assembly.  
3. Slip ferrule up over braid to face of square body and crimp, using ITT Cannon Crimp Tool and  
suitable die set (see table).  
Cable Type  
RG142/U  
RG196/U  
RG316/U  
RG316/U  
RD316  
Cable Code  
9052  
3196  
0000  
3188/9416  
9399  
Die Size  
5,41 (.213)  
2,67 (.105)  
3,25 (.128)  
3,25 (.128)  
3,84 (.151)  
4. Using a small soldering iron solder center conductor to contact.  
NOTE: The center conductor should not protrude beyond the contact to touch the body. Solder  
should not protrude beyond the slotted section of the contact.  
5. Locate the cap in rear of body and dimple or lightly punch to ensure it is locked in position. (A flat  
punch is recommended).  
6. On SMS slip tubing over the ferrule and heat until the shrinkable tubing fits smoothly around the  
cable.  
Only common cable retention features are shown in detail. Various body configurations can apply.  
Dimensions are shown in mm (inch)  
Dimensions subject to change  
120