IS24C01 IS24C02 IS24C04 IS24C08 IS24C16
ISSI
AC ELECTRICAL CHARACTERISTICS (Over Operating Rnage)
Commercial (TA = 0°C to +70°C) Industrial (TA = –40°C to +85°C)
1.8V-5.5V
Min. Max.
2.5V-5.5V
Min. Max.
Symbol Parameter
Test Conditions
Unit
fSCL
SCL Clock Frequency
0
—
4.7
4
4.7
4.7
4.7
4
4
200
0
100
0.1
—
—
—
100
100
—
—
—
—
—
—
—
—
—
—
4.5
1000
300
10
0
—
400
50
—
—
—
—
—
—
—
—
—
—
0.9
300
300
5
KHz
ns
µs
µs
µs
µs
µs
µs
µs
ns
ns
ns
µs
ns
ns
ms
T
Noise Suppression Time(1)
tLOW
tHIGH
tBUF
Clock LOW Period
Clock HIGH Period
1.2
0.6
1.2
0.6
0.6
0.6
0.6
100
0
50
0.1
—
—
—
Bus Free Time Before New Transmission(1)
Start Condition Setup Time
Stop Condition Setup Time
Start Condition Hold Time
Stop Condition Hold Time
Data In Setup Time
Data In Hold Time
Data Out Hold Time
Clock to Output
tSU:STA
tSU:STO
tHD:STA
tHD:STO
tSU:DAT
tHD:DAT
tDH
SCL LOW to SDA Data Out Change
SCL LOW to SDA Data Out Valid
tAA
tR
SCL and SDA Rise Time(1)
SCL and SDA Fall Time(1)
Write Cycle Time
tF
tWR
Note:
1. This parameter is characterized but not 100% tested.
AC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Automotive (TA = –40°C to +125°C)
2.7V-5.5V
4.5V-5.5V
Symbol Parameter
Test Conditions
Min. Max.
Min. Max.
Unit
fSCL
SCL Clock Frequency
0
—
4.7
4
4.7
4.7
4.7
4
4
200
0
100
0.1
—
—
—
100
100
—
—
—
—
—
—
—
—
—
—
4.5
1000
300
10
0
—
400
50
—
—
—
—
—
—
—
—
—
—
0.9
300
300
10
KHz
ns
µs
µs
µs
µs
µs
µs
µs
ns
ns
ns
µs
ns
ns
ms
T
Noise Suppression Time(1)
tLOW
tHIGH
tBUF
Clock LOW Period
Clock HIGH Period
1.2
0.6
1.2
0.6
0.6
0.6
0.6
100
0
50
0.1
—
—
—
Bus Free Time Before New Transmission(1)
Start Condition Setup Time
Stop Condition Setup Time
Start Condition Hold Time
Stop Condition Hold Time
Data In Setup Time
Data In Hold Time
Data Out Hold Time
Clock to Output
tSU:STA
tSU:STO
tHD:STA
tHD:STO
tSU:DAT
tHD:DAT
tDH
SCL LOW to SDA Data Out Change
SCL LOW to SDA Data Out Valid
tAA
tR
SCL and SDA Rise Time(1)
SCL and SDA Fall Time(1)
Write Cycle Time
tF
tWR
Note:
1. This parameter is characterized but not 100% tested.
2. Automotive data is preliminary.
12
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. D
06/25/02