AUIPS1021(
S
)(
R
)
Static Electrical Characteristics
Tj= -40..150°C, Vcc=6..28V (unless otherwise specified), typical value are given for Tj=25°C
Symbol
Rds(on)
Idss1
Idss2
V clamp1
V clamp2
Vin clamp
Vth
Parameter
ON state resistance Tj=25°C
ON state resistance Tj=150°C (2)
Drain to source leakage current
Drain to source leakage current
Drain to source clamp voltage 1
Drain to source clamp voltage 2
IN to source pin clamp voltage
Input threshold voltage
Min.
Typ.
20
38
0.1
0.2
39
39
6.5
1.7
Max.
25
48
2
4
Units
m
µA
Test Conditions
Vin=5V, Ids=8A
Vcc=14V, Tj=25°C
Vcc=28V, Tj=25°C
Id=20mA
Id=2A
Iin=1mA
Id=10mA
36
5.5
42
7.5
V
Switching Electrical Characteristics
Vcc=14V, Resistive load=1.5, Rinput=0, Vin=5V, Tj=25°C
Symbol
Tdon
Tr
Tdoff
Tf
Eon + Eoff
Parameter
Turn-on delay time to 20%
Rise time 20% to 80%
Turn-off delay time to 80%
Fall time 80% to 20%
Turn on and off energy
Min.
10
10
40
15
Typ.
30
30
150
30
2
Max.
100
60
400
60
Units
µs
mJ
Test Conditions
See figure 2
Protection Characteristics
Tj= -40..150°C, Vcc=6..28V (unless otherwise specified), typical value are given for Tj=25°C
Symbol
Tsd
Isd
OV
Vreset
Treset
Parameter
Over temperature threshold
Over current threshold
Over voltage protection ( not active when
the device is ON )
IN protection reset threshold
Time to reset protection
Min.
150(2)
20
34
Typ.
165
45
37
1.7
50
Max.
Units
°C
A
V
V
µs
Test Conditions
See figure 1
See figure 1
58
15(2)
200
Vin=0V
Diagnostic
Tj= -40..150°C, Vcc=6..28V (unless otherwise specified), typical value are given for Tj=25°C
Symbol
Iin, on
Iin, off
Parameter
ON state IN positive current
OFF state IN positive current
(after protection latched)
Min.
15
150
Typ.
32
230
Max.
70
350
Units
µA
Test Conditions
Vin=5V
Vin=5V
(2) Guaranteed by design
www.irf.com
4