欢迎访问ic37.com |
会员登录 免费注册
发布采购

113MT140KBS90 参数 Datasheet PDF下载

113MT140KBS90图片预览
型号: 113MT140KBS90
PDF下载: 下载PDF文件 查看货源
内容描述: 三相控桥 [THREE PHASE CONTROLLED BRIDGE]
分类和应用: 栅极触发装置可控硅整流器局域网
文件页数/大小: 9 页 / 115 K
品牌: IRF [ INTERNATIONAL RECTIFIER ]
 浏览型号113MT140KBS90的Datasheet PDF文件第1页浏览型号113MT140KBS90的Datasheet PDF文件第2页浏览型号113MT140KBS90的Datasheet PDF文件第4页浏览型号113MT140KBS90的Datasheet PDF文件第5页浏览型号113MT140KBS90的Datasheet PDF文件第6页浏览型号113MT140KBS90的Datasheet PDF文件第7页浏览型号113MT140KBS90的Datasheet PDF文件第8页浏览型号113MT140KBS90的Datasheet PDF文件第9页  
53-93-113MT..KB Series
Bulletin I27503 08/97
Blocking
Parameter
V
INS
RMS isolation voltage
53MT.KB 93MT.KB 113MT.KB
52MT.KB 92MT.KB 112MT.KB Units Conditions
51MT.KB 91MT.KB 111MT.KB
4000
500
V
V/µs
T
J
= 25
o
C all terminal shorted
f = 50Hz, t = 1s
T
J
= T
J
max., linear to 0.67 V
DRM
,
gate open circuit
dv/dt Max. critical rate of rise
of off-state voltage (*)
(*) Available with dv/dt = 1000V/ms, to complete code add S90 i.e. 113MT160KBS90.
Triggering
Parameter
P
GM
Max. peak gate power
53MT.KB 93MT.KB 113MT.KB
52MT.KB 92MT.KB 112MT.KB Units Conditions
51MT.KB 91MT.KB 111MT.KB
10
2.5
2.5
10
A
V
W
T
J
= T
J
max.
P
G(AV)
Max. average gate power
I
GM
-V
GT
V
GT
Max. peak gate current
Max. peak negative
gate voltage
Max. required DC gate
voltage to trigger
I
GT
Max. required DC gate
current to trigger
V
GD
I
GD
Max. gate voltage
that will not trigger
Max. gate current
that will not trigger
4.0
2.5
1.7
270
150
80
0.25
V
T
J
= - 40°C
T
J
= 25°C
T
J
= 125°C
T
J
= - 40°C
Anode supply = 6V, resistive load
mA
V
T
J
= 25°C
T
J
= 125°C
Anode supply = 6V, resistive load
@ T
J
= T
J
max., rated V
DRM
applied
6
mA
Thermal and Mechanical Specifications
Parameter
T
J
T
stg
R
thJC
Max. junction operating
temperature range
Max. storage temperature
range
Max. thermal resistance,
junction to case
0.18
1.07
0.19
1.17
R
thCS
Max. thermal resistance,
case to heatsink
T
Mounting
torque ± 10%
wt
to heatsink
to terminal
4 to 6
3 to 4
225
g
Nm
0.14
0.86
0.15
0.91
0.03
0.12
0.70
0.12
0.74
K/W
K/W
DC operation per module
DC operation per junction
120° Rect condunction angle per module
120° Rect condunction angle per junction
Per module
Mounting surface smooth, flat an greased
A mounting compound is recommended and the
torque should be rechecked after a period of 3
hours to allow for the spread of the compound.
Lubricated threads.
53MT.KB 93MT.KB 113MT.KB
52MT.KB 92MT.KB 112MT.KB Units Conditions
51MT.KB 91MT.KB 111MT.KB
-40 to 125
°C
-40 to 125
°C
Approximate weight
www.irf.com
3