IPS4008-xxU
ELECTRICAL CHARACTERISTICS (Tj = 25 ℃ unless otherwise specified)
IPS4008-xxU
Symbol
Test Condition
Unit
03
05
06
08
MIN
10
30
20
50
30
60
50
80
IGT
uA
V
MAX
VD = 6V RL = 100Ω
TYP
0.6
0.8
VGT
MAX
VD=VDRM, RL=3.3KΩ, RGK = 1KΩ
Tj = 110 ℃
VGD
MIN
0.2
V
IL
IG = 1mA RGK = 1KΩ
IT = 50mA RGK = 1KΩ
MAX
MAX
6
5
mA
mA
IH
TYP
1.3
1.7
VTM
IT = 1A t p = 380uS Tj = 25 ℃
V/us
MAX
dV/dt
VD = 67% VDRM RGK = 1KΩ Tj = 110 ℃
VD = VDRM RGK = 1KΩ Tj = 25 ℃
VD = VDRM RGK = 1KΩ Tj = 110 ℃
VR = VRRM RGK = 1KΩ Tj = 25 ℃
VD = VRRM RGK = 1KΩ Tj = 110 ℃
MIN
10
5
V/us
uA
MAX
MAX
MAX
MAX
IDRM
IRRM
0.1
5
mA
uA
0.1
mA
Please ask the IGT values to our sales if you want to get another values.
THERMAL RESISTANCES
Symbol
Parameter
Value
Unit
Rth (j – c)
Junction to case
TO-92
75
℃/W
4F, Cheong won B/D, 269 Hyoje-dong, Jongno-gu, Seoul, 110-480 Korea
Tel : +82-70-7574-2839, Fax : +82-2-6280-6382, sales@ipsemiconductor.com
2