1400 PROVIDENCE HIGHWAY
•
BUILDING 2
NORWOOD, MASSACHUSETTS 02062-5015
6.2 Test Set-Up
The basic test set-up to measure parameters such as efficiency and
load regulation is shown in Figure 1. When testing the Intronics AC60
series under any transient conditions, please ensure that the
transient response of the source is sufficient to power the equipment
under test. We can calculate the
•
•
Efficiency
Load regulation and line regulation.
AC
AC60 Single
Rev A January
2007
6.3 Output Ripple and Noise Measurement
The test set-up for noise and ripple measurements is shown in Figure 2.
Measured method :
Add a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor to
output at 20 MHz Band Width.
Terminal wire 800mmMin
The value of efficiency is defined as:
L
+Vo
+
Load
Vo
×
η
=
Io
× 100%
Pin
Where:
Vo is output voltage,
Io is output current,
Pin is input power,
The value of load regulation is defined as:
Oscilloscope
Supply
N
-Vo
10uF/100V
0.1uF
AC60S Series
Figure 2. Output Voltage Ripple and Noise Measurement Set-Up
V
Load reg
=
NL FL
-V × 100%
V
NL
6.4 Installation Instruction
Please use the mounting hold as:
AC60 series :
4 holds of
ψ3.17
And insert the spacer (Maxψ6) of height over 8mm to lift the unit .The
vibration spec. is the value take when the unit is raised by 8mm spacers.
Where V
FL
is the output voltage at full load
V
NL
is the output voltage at 10% load
The value of line regulation is defined as:
Where V
HL
is the output voltage of maximum input voltage at full load.
V
LL
is the output voltage of minimum input voltage at full load.
Line reg
=
V
HL
−
V
V
LL
LL
× 100%
AC
Pin
Supply
L
+Vo
V
A
Load
N
-Vo
+
Figure 1. AC60 Series Test Setup
Page
6