CA3140, CA3140A  
placed across the input to the CA3080A to give a logarithmic  
analog indication of the function generator’s frequency.  
7
6
5
4
3
2
1
0
o
T
= 125 C  
A
FOR METAL CAN PACKAGES  
DIFFERENTIAL DC VOLTAGE  
(ACROSS TERMINALS 2 AND 3) = 2V  
OUTPUT STAGE TOGGLED  
Analog frequency readout is readily accomplished by the  
means described above because the output current of the  
CA3080A varies approximately one decade for each 60mV  
change in the applied voltage, V  
(voltage between  
ABC  
Terminals 5 and 4 of the CA3080A of the function generator).  
Therefore, six decades represent 360mV change in V  
.
ABC  
Now, only the reference voltage must be established to set  
the lower limit on the meter. The three remaining transistors  
from the CA3086 Array used in the sweep generator are  
used for this reference voltage. In addition, this reference  
generator arrangement tends to track ambient temperature  
variations, and thus compensates for the effects of the  
normal negative temperature coefficient of the CA3080A  
DIFFERENTIAL DC VOLTAGE  
(ACROSS TERMINALS 2 AND 3) = 0V  
OUTPUT VOLTAGE = V+ / 2  
0
500 1000 1500 2000 2500 3000 3500 4000 4500  
TIME (HOURS)  
FIGURE 9. TYPICAL INCREMENTAL OFFSET VOLTAGE  
SHIFT vs OPERATING LIFE  
V
terminal voltage.  
ABC  
Super Sweep Function Generator  
Another output voltage from the reference generator is used  
to insure temperature tracking of the lower end of the  
Frequency Adjustment Potentiometer. A large series  
resistance simulates a current source, assuring similar  
temperature coefficients at both ends of the Frequency  
Adjustment Control.  
A function generator having a wide tuning range is shown in  
Figure 10. The 1,000,000/1 adjustment range is  
accomplished by a single variable potentiometer or by an  
auxiliary sweeping signal. The CA3140 functions as a non-  
inverting readout amplifier of the triangular signal developed  
across the integrating capacitor network connected to the  
output of the CA3080A current source.  
To calibrate this circuit, set the Frequency Adjustment  
Potentiometer at its low end. Then adjust the Minimum  
Frequency Calibration Control for the lowest frequency. To  
establish the upper frequency limit, set the Frequency  
Adjustment Potentiometer to its upper end and then adjust  
the Maximum Frequency Calibration Control for the  
maximum frequency. Because there is interaction among  
these controls, repetition of the adjustment procedure may  
be necessary. Two adjustments are used for the meter. The  
meter sensitivity control sets the meter scale width of each  
decade, while the meter position control adjusts the pointer  
on the scale with negligible effect on the sensitivity  
Buffered triangular output signals are then applied to a  
second CA3080 functioning as a high speed hysteresis  
switch. Output from the switch is returned directly back to the  
input of the CA3080A current source, thereby, completing  
the positive feedback loop  
The triangular output level is determined by the four 1N914  
level limiting diodes of the second CA3080 and the resistor  
divider network connected to Terminal No. 2 (input) of the  
CA3080. These diodes establish the input trip level to this  
switching stage and, therefore, indirectly determine the  
amplitude of the output triangle.  
adjustment. Thus, the meter sensitivity adjustment control  
1
calibrates the meter so that it deflects / of full scale for  
6
Compensation for propagation delays around the entire loop  
is provided by one adjustment on the input of the CA3080.  
This adjustment, which provides for a constant generator  
amplitude output, is most easily made while the generator is  
sweeping. High frequency ramp linearity is adjusted by the  
single 7pF to 60pF capacitor in the output of the CA3080A.  
each decade change in frequency.  
Sine Wave Shaper  
The circuit shown in Figure 12 uses a CA3140 as a voltage  
follower in combination with diodes from the CA3019 Array  
to convert the triangular signal from the function generator to  
a sine-wave output signal having typically less than 2% THD.  
The basic zero crossing slope is established by the 10kΩ  
potentiometer connected between Terminals 2 and 6 of the  
CA3140 and the 9.1kresistor and 10kpotentiometer  
from Terminal 2 to ground. Two break points are established  
It must be emphasized that only the CA3080A is  
characterized for maximum output linearity in the current  
generator function.  
Meter Driver and Buffer Amplifier  
by diodes D through D . Positive feedback via D and D  
establishes the zero slope at the maximum and minimum  
levels of the sine wave. This technique is necessary because  
the voltage follower configuration approaches unity gain  
rather than the zero gain required to shape the sine wave at  
the two extremes.  
1
4
5
6
Figure 11 shows the CA3140 connected as a meter driver  
and buffer amplifier. Low driving impedance is required of  
the CA3080A current source to assure smooth operation of  
the Frequency Adjustment Control. This low-driving  
impedance requirement is easily met by using a CA3140  
connected as a voltage follower. Moreover, a meter may be  
FN957.10  
10  