PRESSURE OUTPUT CHARACTERISTICS  
With the calibration data stored in the interface IC of the MS5540B the following characteristics can be achieved:  
(VDD = 3.0 V unless noted otherwise)  
Parameter  
Conditions  
Min  
Typ  
Max  
Unit  
mbar  
mbar  
Notes  
Resolution  
0.1  
1
2
p = 750 .. 1100 mbar  
Ta = 25°C  
p = 750 .. 1100 mbar  
Ta = 25°C  
Absolute Pressure Accuracy  
-1.5  
-0.5  
-1  
+1.5  
+0.5  
+1  
Relative Pressure Accuracy  
Error over Temperature  
mbar  
mbar  
3
4
T = 0 .. +50°C  
p = 300 .. 1000 mbar  
T = -40 .. +85°C  
p = 300 .. 1000 mbar  
-1  
+3  
mbar  
mbar  
mbar  
4
5
Long-term Stability  
12 months  
-1  
Maximum Error over Supply  
Voltage  
VDD = 2.2 .. 3.6 V  
p = const.  
-1.6  
+1.6  
NOTES  
1) A stable pressure reading of the given resolution requires taking the average of 2 to 4 subsequent pressure  
values due to noise of the ADC.  
2) Maximum error of pressure reading over the pressure range.  
3) Maximum error of pressure reading over the pressure range after offset adjustment at one pressure point.  
4) With the second-order temperature compensation as described in Section “FUNCTION". See next section  
for typical operating curves.  
5) The long-term stability is measured with non-soldered devices.  
TEMPERATURE OUTPUT CHARACTERISTICS  
This temperature information is not required for most applications, but it is necessary to allow for temperature  
compensation of the pressure output.  
(VDD = 3.0 V unless noted otherwise)  
Parameter  
Conditions  
Min  
0.005  
-0.8  
Typ  
Max  
0.015  
0.8  
Unit  
°C  
Notes  
Resolution  
T = 20°C  
°C  
Accuracy  
T = -40 .. +85°C  
°C  
1
± 2  
Maximum Error over Supply  
Voltage  
VDD = 2.2 .. 3.6 V  
-0.2  
+ 0.2  
°C  
NOTES  
1) With the second-order temperature compensation as described in Section “FUNCTION". See next section  
for typical operating curves.  