APPLICATION INFORMATION  
GENERAL  
The advantage of combining a pressure sensor with a directly adapted integrated circuit is to save other external  
components and to achieve a very low power consumption. The main application field for this system includes  
portable devices with battery supply, but its high accuracy and resolution make it also suited for industrial and  
automotive applications. The possibility to compensate the sensor with a software allows the user to adapt it to  
his particular application. Communication between the MS5540B and the widely available microcontrollers is  
realised over an easy-to-use 3-wire serial interface. Customers may select which microcontroller system to be  
used, and there are no specific standard interface cells required, which may be of interest for specially designed  
4 Bit-microcontroller applications.  
CALIBRATION  
The MS5540B is factory calibrated. The calibration data is stored inside the 64-Bit PROM memory.  
SOLDERING  
Please refer to the application note AN808 for all soldering issues.  
HUMIDITY, WATER PROTECTION  
The silicon pressure transducer and the bonding wires are protected by a anticorrosive and antimagnetic  
protection cap. The MS5540B carries a metal protection cap filled with silicone gel for enhanced protection  
against humidity. The properties of this gel ensure function of the sensor even when in direct water contact. This  
feature can be useful for waterproof watches or other applications, where direct water contact cannot be  
avoided. Nevertheless the user should avoid drying of hard materials like for example salt particles on the  
silicone gel surface. In this case it is better to rinse with clean water afterwards. Special care has to be taken to  
not mechanically damage the gel. Damaged gel could lead to air entrapment and consequently to unstable  
sensor signal, especially if the damage is close to the sensor surface.  
The metal protection cap is fabricated of special anticorrosive and antimagnetic stainless steel in order to avoid  
any corrosive battery effects inside the final product. The MS5540B is qualified referring to the ISO Standard  
2281 and can withstand a pressure of 11 bar in salt water. The concentration of the see water used for the  
qualification is 41 g of see salt for 1 litre of DI water.  
For underwater operations as specified in ISO Standard 2281 it is important to seal the sensor with a rubber O-  
ring around the metal cap. Any salt water coming to the contact side (ceramic and pads) of the sensor could lead  
to permanent damage. Especially for "water-resistant 100 m" watches it is recommended to provide a stable  
mechanical pusher from the backside of the sensor. Otherwise the overpressure might push the sensor  
backwards and even bend the electronic board on which the sensor is mounted.  
LIGHT SENSITIVITY  
The MS5540B is protected against sunlight by a layer of white gel. It is, however, important to note that the  
sensor may still be slightly sensitive to sunlight, especially to infrared light sources. This is due to the strong  
photo effect of silicon. As the effect is reversible there will be no damage, but the user has to take care that in  
the final product the sensor cannot be exposed to direct light during operation. This can be achieved for instance  
by placing mechanical parts with holes in such that light cannot pass.  
CONNECTION TO PCB  
The package outline of the module allows the use of a flexible PCB to connect it. This can be important for  
applications in watches and other special devices, and will also reduce mechanical stress on the device.  
For applications subjected to mechanical shock, it is recommended to enhance the mechanical reliability of the  
solder junctions by covering the rim or the corners of MS5540B's ceramic substrate with glue or Globtop-like  
material.  