MSM SERIES
5 WATT
DC/DC CONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
MSM2812D
MIN TYP MAX
MSM2815D
MIN TYP MAX
14.78 15 15.23
CONDITIONS
Tc = 25°C
UNITS
VDC
mA
11.82 12
12.18
—
V
V
= 16 TO 40 VDC
0
208
0
167
—
IN
IN
1
OUTPUT POWER
= 16 TO 40 VDC
0
—
5
0
—
5
W
OUTPUT RIPPLE
10 kHz - 2 MHz
—
—
180
—
—
—
—
150
—
—
VOLTAGE +V
Tc = –55°C TO +125°C
1200
1000
OUT
OUT
mV p-p
–V
10 kHz - 2 MHz
—
—
—
180
1200
120
—
—
—
—
—
—
150
1000
150
—
—
—
Tc = –55°C TO +125°C
LINE REGULATION
= 16 TO 40 VDC
+V
OUT
mV
mV
V
–V
—
—
—
120
350
350
—
—
—
—
—
—
150
400
400
—
—
—
OUT
IN
LOAD REGULATION
NO LOAD TO FULL
+V
OUT
–V
OUT
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
CONTINUOUS
TRANSIENT 120 ms
NO LOAD
16
0
28
—
40
80
—
—
—
16
0
28
—
40
80
—
—
—
VDC
V
—
—
—
20
—
—
—
16
FULL LOAD
230
4.5
220
4.5
mA
INHIBITED
INPUT RIPPLE
CURRENT
10 kHz - 2 MHz
—
—
—
20
120
80
—
—
—
—
—
—
15
100
82
—
—
—
mA p-p
%
Tc = –55°C TO +125°C
EFFICIENCY
LOAD FAULT
POWER DISSIPATION
OVERLOAD
—
—
—
1.7
0.8
8.0
—
—
—
—
—
—
1.5
0.7
7.5
—
—
—
W
2
SHORT CIRCUIT
3
RECOVERY
ms
OUTPUT CURRENT
TRIP POINT
—
—
350
380
—
—
—
—
280
300
—
—
mA
SHORT CIRCUIT
50 %–100%– 50%
STEP LOAD
4
RESPONSE
V
V
TRANSIENT
—
—
400
1
—
—
—
—
400
1
—
—
mV pk
ms
OUT
OUT
3
RECOVERY
STEP LINE
RESPONSE
16 TO 40 TO 16 V
IN
4
TRANSIENT
—
500
—
—
500
—
mV pk
3
RECOVERY
—
—
—
2
4
—
—
—
—
—
—
2
—
—
—
ms
ms
START–UP
V
DELAY
3.5
400
OUT
OVERSHOOT
350
mV pk
Notes:
1. The maximum specification indicates the converter’s total output power, Up
to 75% of the total is available from either output providing the other output
maintains a minimum of 25% of the total power.
3. Time to settle within 1% of V
OUT
4. Transition ≥ 10 µs.
2. Short circuit is measured with a 50 mohm resistive load.
3