F
ACTORY
C
ONFIGURABLE
DC/DC C
ONVERTERS
30 Watt Dual Output Modules
MDC SERIES
UP TO 60 WATTS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODULES
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
1, 2
OUTPUT POWER
1, 2
OUTPUT RIPPLE
VOLTAGE +/– V
OUT
LINE REGULATION
3
V
IN
= 16 TO 40 VDC
Tc = –55°C
TO +125°C
LOAD REGULATION
NO LOAD TO FULL
Tc = –55°C
TO +125°C
CROSS REGULATION
EFFECT ON –V
OUT
INPUT VOLTAGE
1
NO LOAD TO FULL
INPUT CURRENT
SEE NOTE 4
SEE NOTE 5
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
FULL LOAD
INHIBITED
10 kHz - 10 MHz
POWER DISSIPATION
SHORT CIRCUIT
1
RECOVERY
50 – 100 – 50% BALANCED
TRANSIENT
RECOVERY
7
16 – 40 – 16 V
IN
TRANSIENT
8
RECOVERY
7
START–UP
1
DELAY
OVERSHOOT
FULL LOAD
NO LOAD
—
—
0
50
50
250
—
—
0
120
120
600
—
—
0
150
150
750
mV pk
CONDITIONS
+V
OUT
–V
OUT
V
IN
= 16 TO 40 VDC
V
IN
= 16 TO 40 VDC
10 kHz - 2 MHz
Tc = –55°C TO +125°C
+V
OUT
–V
OUT
+V
OUT
–V
OUT
+V
OUT
–V
OUT
+V
OUT
–V
OUT
MIN
4.95
4.92
0
0
—
—
—
—
—
—
—
—
—
—
—
—
16
0
—
—
—
—
76
—
—
—
—
—
—
—
05D
TYP
5.00
5.00
2.5
—
20
40
10
50
10
50
5
25
5
25
7
4
28
—
35
1.10
3
15
78
—
1.4
±200
100
±200
—
1.4
MAX
5.05
5.07
4.5
25
50
80
50
100
50
100
30
50
50
100
12
6
40
50
75
—
8
50
—
10
5.0
±300
200
±400
300
5
MIN
11.88
11.82
0
0
—
—
—
—
—
—
—
—
—
—
—
—
16
0
—
—
—
—
78
—
—
—
—
—
—
—
12D
TYP
12.00
12.00
1.25
—
30
40
10
50
10
50
15
30
15
30
4
4
28
—
50
1.34
3
20
81
—
1.4
±150
100
±200
—
1.4
MAX
12.12
12.18
2.25
30
80
120
30
120
50
150
30
120
50
180
8.3
6
40
50
75
—
8
50
—
10
5.0
±300
200
±400
300
5
MIN
14.85
15D
TYP
15.00
MAX
15.15
15.23
1.8
30
80
120
30
150
50
180
30
150
50
180
8
6
40
50
75
—
8
50
—
10
5.0
±400
200
±500
300
5
%
VDC
V
mA
A
mA
mA p-p
%
W
ms
mV pk
µs
mV pk
µs
ms
mV
mV
A
W
mV p-p
UNITS
VDC
14.77 15.00
0
0
—
—
—
—
—
—
—
—
—
—
—
—
16
0
—
—
—
—
80
—
—
—
—
—
—
—
1.0
—
25
40
10
50
10
50
15
30
15
30
3
4
28
—
50
1.29
3
20
83
—
1.4
±200
100
±400
—
1.4
INPUT RIPPLE
CURRENT
1
EFFICIENCY
LOAD FAULT
6
STEP LOAD
RESPONSE ± V
OUT
STEP LINE
RESPONSE ± V
OUT
Notes
1.Tc = –55°C to +100°C.
2. Up to 90% of the total output current/power is available from either output
providing the positive output is carrying at least 10% of the total output
power.
3. Operation
is
limited
below
16
V
(see
Figure
21).
+P
out
20% to 80%; –P
out
80% to 20%
5. Effect on the negative output under the following conditions:
+P
out
50%; –P
out
10% to 50%
6. Indefinite short circuit protection not guaranteed above 100°C case.
7. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
8. Transition time
≥
10 µs.
5