MCH SERIES
1.5 WATT
DC/DC CONVERTERS
E
NVIRONMENTAL CREENING
S
TEST
125°C
125°C
STANDARD
/ES
/883 (Class H)*
PRE-CAP INSPECTION
Method 2017, 2032
yes
yes
yes
TEMPERATURE CYCLE (10 times)
Method 1010, Cond. C, -65°C to 150°C
Method 1010, Cond. B, -55°C to 125°C
no
no
no
yes
yes
no
CONSTANT ACCELERATION
Method 2001, 3000 g
Method 2001, 500 g
no
no
no
yes
yes
no
BURN-IN
Method 1015, 160 hours at 125°C
96 hours at 125°C case (typical)
no
no
no
yes
yes
no
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C
Subgroups 1 and 4: +25°C case
no
yes
no
yes
yes
no
HERMETICITY TESTING
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10 )
no
no
yes
yes
yes
no
yes
yes
no
-3
FINAL VISUAL INSPECTION
Method 2009
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
*883 products are built with element evaluated components and are 100% tested and guaranteed over
Contact Information:
www.interpoint.com
Interpoint Headquarters USA
Phone: 1-800-822-8782
+425-882-3100
Interpoint UK
Phone: +44-1252-872266
Interpoint France
Phone: +33-134285455
Email:
poweruk@intp.com
Email:
powerfr@intp.com
Email:
power@intp.com
22422-001-DTS Rev C This revision supercedes all previous releases.
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
products or specifications without notice. MGA Series is a trademark of Interpoint.
Copyright © 1997 - 2000 Interpoint. All rights reserved.