QUALITY ASSURANCE
C
LASS
H, QML S
CREENING
TEST
125°C
STANDARD
non-QML
125°C
/ES
non-QML
Class H
/883
QML
Pre-cap Inspection
Method 2017, 2032
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
Method 1010, Cond. B, -55°C to 125°C, ambient
Constant Acceleration
Method 2001, 3000 g
Method 2001, 500g
Burn-In
Method 1015, 160 hours at 125°C case, typical
96 hours at 125°C case, typical
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C case
Subgroups 1 and 4: +25°C case
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10
-3
)
Final Visual Inspection
Method 2009
yes
yes
yes
no
no
no
yes
yes
no
no
no
no
yes
yes
no
no
no
no
yes
yes
no
no
yes
no
yes
yes
no
no
no
yes
yes
yes
no
yes
yes
no
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Class H,
QML Screening
page 1 of 1
QA Screening Class H, QML Rev B November 1, 2005 (typo).
This revision supercedes all previous releases. All technical infor-
mation is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to
make changes in products or specifications without notice.
Copyright © 2005 Interpoint Corporation. All rights reserved.