FM-704A EMI FILTER
40 WATT
ABSOLUTE MAXIMUM RATINGS
Input Voltage
• 16 to 40 VDC continuous for 40 W load
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –65°C to +150°C
EMI I
NPUT
F
ILTERS
INHIBIT
Inhibit TTL Open Collector
• Logic low (output disabled)
Logic low voltage
≤0.8
V
Logic low inhibit pin current 0.6 mA max
• Referenced to input common
• Logic high (output enabled)
Open collector
TYPICAL CHARACTERISTICS
Capacitance
• 0.017 µF max, any pin to case
Undervoltage lockout
• 7 VDC min, 15 VDC max
Isolation
• 100 megohm minimum at 500 V
• Any pin to case, except case pin
Inhibit Pin Voltage (unit enabled)
• 5.5 V max
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 16 to 40 VDC continuous for 40 W load
Case Operating Temperature (Tc)
• –55°C to +125°C
Derating Output Power
• Linearly from 40 W at 105°C to 25 W at 125°C to meet
MIL-STD-1275A (AT) and MIL-STD-704A
Electrical Characteristics: 25°C Tc, nominal Vin, unless otherwise specified.
PARAMETER
INPUT VOLTAGE
CONDITIONS
NO LOAD
40 W LOAD
UNDERVOLTAGE LOCKOUT
16 V
IN
40 V
IN
NO LOAD
INHIBITED
40 W, 100 V, 0.5
Ω
Z
S
, 60 ms
1
40 W, 400 V, 0.5
Ω
Z
S
, 5 µs
2
40 W, 600 V, 50
Ω
Z
S
, 10 µs
3
500 kHz
1 MHz
Tc = 25°C
STEADY STATE
INHIBITED
16 V
IN
40 V
IN
PEAK
105°C
125°C
CONTINUOUS ( > 10 SEC.)
105°C
125°C
—
—
—
INPUT CURRENT
MIN
0
16
7
—
—
FM-704A
TYP
28
28
—
—
—
INPUT SURGE
INPUT SPIKE
DIFFERENTIAL MODE
NOISE REJECTION
DC RESISTANCE (R
DC
)
OUTPUT VOLTAGE
OUTPUT CURRENT
INTERNAL POWER
DISSIPATION
—
—
42
—
—
60
55
—
—
—
—
—
—
—
—
—
V
OUT
= V
IN
- I
IN
(R
DC
)
—
—
—
MAX
40
40
15
2.5
1.0
5
2
48
48
48
—
—
0.45
1
2.5
1.0
1000
500
30
15
UNITS
VDC
A
mA
V
OUT
V
OUT
dB
Ω
VDC
A
—
—
—
—
—
—
—
—
W
Notes
1. Meets MIL-STD-1275A (AT) Surge and Figure 8 and 9 of MIL-STD-704A. For these standards derate output power linearly from 40 W at 105°C to 25
W at 125°C.
2. Meets Panavia SP-P-90001, British Standard BS3G100 and Civil Aircraft D0160 Standards.
3. Meets MIL-STD-461C 1.2 CS06 limits.
B3-4