Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
Electrical Characteristics: -55°C to +125°C T
C
, 28 VDC Vin, 100% load, RHA level O, unless otherwise specified.
SINgLE OuTPuT MODELS
Parameter
OutPut VOltage
OutPut current
OutPut POWer
OutPut riPPle
10
k
h
z
- 2 mh
z
line regulatiOn
lOaD regulatiOn
inPut VOltage
inPut current
V
in
= 16
tO
40 VDc
V
in
= 16
tO
40 VDc
t
c
= -55°c
tO
+125°c
V
in
= 16
tO
40 VDc
nO lOaD tO Full
cOntinuOuS
TRANSIENT 50 ms
1,2
nO lOaD
inhibiteD – inh1
inhibiteD – inh2
inPut riPPle
eFFiciency
lOaD Fault
10
k
h
z
- 10 mh
z
t
c
= -55°c
tO
+125°c
t
c
= 25°c
t
c
= 25°c
cOnDitiOnS
MIN
11.76
0
0
—
—
—
—
16
—
—
—
—
—
81
79
—
SMFL2812S
TYP
12.00
—
—
0
45
0
—
28
—
50
9
35
30
84
—
10
1.5
—
—
—
—
—
—
±450
1.5
±250
200
3.5
—
MAx
12.24
5
60
75
100
20
40
40
80
100
14
70
50
—
—
16
4
±600
3.0
±400
300
6
1000
—
—
—
—
—
—
MIN
SMFL2815S
TYP
15.00
—
—
30
45
0
—
28
—
50
9
35
30
85
—
10
1.5
±500
1.5
±250
200
3.5
—
MAx
15.45
4.33
65
85
110
20
20
40
80
100
14
70
50
—
—
16
4
±600
3.0
±500
300
6
1000
14.55
0
0
—
—
—
—
16
—
—
—
—
—
82
80
—
unitS
VDc
a
W
mV p-p
mV
mV
VDc
V
mA
mA p-p
%
W
ms
mV pk
ms
mV pk
µs
ms
µF
ShOrt circuit
POWer DiSSiPatiOn
recOVery
1
50% - 100% - 50%
tranSient
recOVery
1,
3
16 - 40 -16 VDc
tranSient
recOVery
Delay
t
c
= 25°c
SteP lOaD reSPOnSe
SteP line
reSPOnSe
1,
3
Start-uP
4
CAPACITIVE LOAD
5
Notes
1. guaranteed by design, not tested.
2. unit will shut down above approximately 45 V but will be undamaged and will
restart when voltage drops into normal range.
3. Recovery time is measured from application of the transient to point at
which V
OuT
is within 1% of final value.
4. Tested on release from inhibit.
5. Shall not compromise DC performance.
www.craneae.com/interpoint
Page 7 of 14
SMFL Rev AA - 2012.03.19