MOR SERIES
120 WATT
DC/DC CONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE AND DUAL OUTPUT MODELS
MOR2812S
MOR2815S
MOR283R3D
MOR2805D
PARAMETER
CONDITIONS
MIN TYP MAX
MIN TYP MAX
MIN TYP MAX
MIN TYP MAX
UNITS
5
OUTPUT VOLTAGE
+V
–V
11.88 12.00 12.12
14.85 15.00 15.15
3.25 3.30 3.35
4.95 5.00 5.05
OUT
VDC
—
0
—
—
—
—
9.2
110
—
0
—
—
—
—
8
3.22 3.30 3.38
6
4.92 5.00 5.08
6
OUT
OUTPUT CURRENT
OUTPUT POWER
V
V
= 16 to 40 VDC
= 16 to 40 VDC
—
—
10 20
—
—
10 20
A
IN
IN
6
6
—
—
120
—
66
—
100
W
OUTPUT RIPPLE
VOLTAGE
10 kHz - 20 MHz
Tc = –55°C to +125°C
10 kHz - 2 MHz
—
75
120
—
75
150
—
50
80
—
50
80
mV p-p
+V
OUT
,
V
OUT
Tc = –55°C to +125°C
—
—
50
0
100
20
—
—
50
0
120
20
—
—
35
25
50
50
—
—
35
25
50
50
LINE REGULATION
= 16 to 40 VDC
+V
OUT
mV
mV
V
–V
—
—
—
—
—
—
—
50
100
—
50
100
IN
OUT
LOAD REGULATION
+V
—
—
0
20
—
—
—
0
20
—
—
—
25
50
50
—
—
25
50
50
OUT
–V
—
—
150
150
OUT
7
CROSS REGULATION
INPUT VOLTAGE
NEGATIVE V
OUT
—
—
—
—
—
—
—
6
10
40
—
5
8
%
CONTINUOUS
16
28
40
16
28
40
16
28
16
28
40
VDC
TRANSIENT 120 msec
NO LOAD
—
—
—
—
—
—
70
—
—
—
50
130
4.72
10
—
—
—
—
—
—
70
—
—
—
50
130
5.10
10
—
—
—
—
—
—
70
—
—
—
50
140
3.2
10
—
—
—
—
—
—
70
—
—
—
50
140
4.67
10
V
mA
A
INPUT CURRENT
FULL LOAD
INHIBITED - INH1
INHIBITED - INH2
10 kHz - 20 MHz
Tc = –55°C to +125°C
mA
70
70
70
70
INPUT RIPPLE
CURRENT
—
50
86
130
—
—
50
87
130
—
—
60
77
130
—
—
60
81
130
—
mA p-p
%
EFFICIENCY
84
84
76
78
1
LOAD FAULT
POWER DISSIPATION
OVERLOAD
—
—
—
—
—
—
30
22
10
—
—
—
—
—
—
30
22
10
—
—
—
—
—
—
27
22
10
—
—
—
—
—
—
30
27
10
W
2
SHORT CIRCUIT
RECOVERY
OUTPUT CURRENT
TRIP POINT
ms
—
—
—
—
12
11
—
—
—
—
10
9
—
—
—
—
25
24
—
—
—
—
25
24
A
2
SHORT CIRCUIT
STEP LOAD RESP.
50% – 100% — 50%
TRANSIENT
+V
OUT
,
V
—
—
—
—
600
300
—
—
—
—
600
300
—
—
—
—
250
200
—
—
—
—
250
200
mV pk
µs
OUT
3
RECOVERY
STEP LINE RESP.
+V
16 – 40 – 16 VDC
4
,
V
TRANSIENT
—
—
—
—
—
—
—
600
300
10
—
—
—
—
—
—
—
600
300
10
—
—
—
—
—
—
—
400
300
10
—
—
—
—
—
—
—
400
300
10
mV pk
µs
OUT
OUT
3
RECOVERY
START-UP
DELAY
—
—
—
—
ms
OVERSHOOT
UNIT INHIBITED
—
50
—
50
—
25
—
50
mV pk
mA
INHIBIT PIN CURRENT
0.1
1.0
0.1
1.0
0.1
1.0
0.1
1.0
Notes:
6. The maximum specification is the total output current/power. Up to 70%
of that total is available from either output provided the other output
maintains a minimum of 15% the total power used.
1. Load fault conditions are measured with a resistive load.
2. Short circuit is measured with a 10 m W ( 10%) load.
3. Time to settle to within 1% of Vout.
7. Cross regulation percentages are for the following conditions:
4. Transition time > 10 µs
5. Output voltage for dual output models is measured at half load.
+Po = 30% and –Po = 70%
+Po = 70% and –Po = 30%
+Po = 10% and –Po = 50%
+Po = 50% and –Po = 10%
3