MHP270 SERIES
65 WATT
DC/DC C
ONVERTERS
T
ABLE
1: E
NVIRONMENTAL
S
CREENING
STANDARD
/ES
TEST (125°C Products)
PRE-CAP INSPECTION
Method 2017, 2032
TEMPERATURE CYCLE (10 times)
Method 1010, Cond. B, -55°C to 125°C
CONSTANT ACCELERATION
Method 2001, 500 g
BURN-IN
96 hours at 125°C case (typical)
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
HERMETICITY TESTING
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10
-3
)
FINAL VISUAL INSPECTION
Method 2009
yes
yes
no
yes
no
yes
no
yes
yes
yes
no
no
yes
yes
yes
no
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.