Crane Aerospace & Electronics Power Solutions
MSA/MGA Single and Dual DC-DC Converters
28 Volt input – 5 WAtt
S
tanDarD
M
iCrOCirCuit
D
rawing
(SMD)
5962-9309201HxC
5962-0251301HxC
5962-9309301HxC
5962-9309401HxC
5962-0052201HxC
5962-9308901HxC
5962-9309001HxC
sMD nuMbers
MSa S
iMilar
p
art
S
tanDarD
M
iCrOCirCuit
D
rawing
(SMD)
5962-9309201HZC
5962-9309301HZC
5962-9309401HZC
5962-0052201HZC
5962-9308901HZC
5962-9309001HZC
sMD nuMbers
Mga S
iMilar
p
art
MSA2805S/883
MSA285R2S/883
MSA2812S/883
MSA2815S/883
MSA2805D/883
MSA2812D/883
MSA2815D/883
MGA2805SZ/883
MGA2812SZ/883
MGA2815SZ/883
MGA2805DZ/883
MGA2812DZ/883
MGA2815DZ/883
For exact specifications for an SMD product, refer to
the SMD drawing. SMDs can be downloaded from:
http://www.landandmaritime.dla.mil/programs/smcr
t
able
5: msa smD n
umbers
For exact specifications for an SMD product, refer
to the SMD drawing. SMD numbers are shown for
the surface mount gull-wing case. For the straight-
lead case, replace the Z (HZC) in the SMD with a Y
(HYC). SMDs can be downloaded from: http://www.
landandmaritime.dla.mil/programs/smcr
t
able
6: mga smD n
umbers
MoDel nuMberinG key
Base Model
MSA
28 12
Input Voltage
Output Voltage
(R = decimal point, 5R2 = 5.2 Vout)
Number of Outputs
(S = single, D = dual)
MoDel nuMberinG key
Base Model
Input Voltage
MGA
28 12 S
Z / 883
D / 883
Output Voltage
Number of Outputs
(S = single, D = dual)
Gull Wing Lead Option
(Straight leaded case has no designator
in this position.)
Screening
(Standard screening has no designator
in this position.)
Screening
(Standard screening has no designator
in this position.)
F
igure
7: msa m
oDel
n
umbering
k
ey
F
igure
8: mga m
oDel
n
umbering
k
ey
t
O
cateGory
DeterMine the MODel nuMber enter One OptiOn frOM eaCh CategOry in the fOrM belOw
.
base Model and
input Voltage
MSA
MGA
output Voltage
1
05, 5R2, 12, 15
05, 12, 15
number of
outputs
2
S
D
case options
3
MSA – down-leaded: leave blank
MGA – straight leads: leave blank
MGA – gull wings: Z
__________
M A
__________
/
screening
4
(standard, leave blank)
ES
883
MoDel nuMber options
options
Fill in For
MoDel #
Notes:
1. 5R2 is a 5.2 output model.
2. Number of Outputs: S is a single output and D is a dual output
3. Case Options: For the MSA down-leaded case leave the case option blank. For the MGA straight-lead case, leave the case option blank. For the MGA, surface mount
gull-wing case, insert the letter “Z” in the case option position.
4. Screening: For standard screening leave the screening option blank. For other screening options, insert the desired screening level. For more information see
“Table 11: Element Evaluation” on page 12 and “Table 12: Environmental Screening” on page 13.
t
able
7: msa
www.craneae.com/interpoint
anD
mga m
oDel
n
umber
o
ptions
Page 5 of 15
MSA_MGA Rev AC - 2013.06.13