MAX 7000A Programmable Logic Device Data Sheet
The parameters in this equation are:
MCTON
=
Number of macrocells with the Turbo Bit option turned
on, as reported in the MAX+PLUS II Report File (.rpt)
Number of macrocells in the device
Total number of macrocells in the design, as reported in
the Report File
MCDEV
MCUSED
=
=
fMAX
togLC
=
=
Highest clock frequency to the device
Average percentage of logic cells toggling at each clock
(typically 12.5%)
A, B, C
=
Constants, shown in Table 28
Table 28. MAX 7000A ICC Equation Constants
Device
A
B
C
EPM7032AE
EPM7064AE
EPM7128A
EPM7128AE
EPM7256A
EPM7256AE
EPM7512AE
0.71
0.71
0.71
0.71
0.71
0.71
0.71
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.014
0.014
0.014
0.014
0.014
0.014
0.014
This calculation provides an ICC estimate based on typical conditions
using a pattern of a 16-bit, loadable, enabled, up/down counter in each
LAB with no output load. Actual ICC should be verified during operation
because this measurement is sensitive to the actual pattern in the device
and the environmental operating conditions.
Altera Corporation
51