欢迎访问ic37.com |
会员登录 免费注册
发布采购

EPM3064ATC100-7N 参数 Datasheet PDF下载

EPM3064ATC100-7N图片预览
型号: EPM3064ATC100-7N
PDF下载: 下载PDF文件 查看货源
内容描述: [EE PLD, 7.5ns, 64-Cell, CMOS, PQFP100, TQFP-100]
分类和应用: 时钟输入元件可编程逻辑
文件页数/大小: 46 页 / 711 K
品牌: INTEL [ INTEL ]
 浏览型号EPM3064ATC100-7N的Datasheet PDF文件第35页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第36页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第37页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第38页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第40页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第41页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第42页浏览型号EPM3064ATC100-7N的Datasheet PDF文件第43页  
MAX 3000A Programmable Logic Device Family Data Sheet  
Supply power (P) versus frequency (fMAX, in MHz) for MAX 3000A  
devices is calculated with the following equation:  
Power  
Consumption  
P = PINT + PIO = ICCINT × VCC + PIO  
The PIO value, which depends on the device output load characteristics  
and switching frequency, can be calculated using the guidelines given in  
Application Note 74 (Evaluating Power for Altera Devices).  
The ICCINT value depends on the switching frequency and the application  
logic. The ICCINT value is calculated with the following equation:  
ICCINT  
=
(A × MCTON) + [B × (MCDEV – MCTON)] + (C × MCUSED × fMAX × togLC  
)
The parameters in the ICCINT equation are:  
MCTON  
=
Number of macrocells with the Turbo BitTM option turned  
on, as reported in the Quartus II or MAX+PLUS II Report  
File (.rpt)  
MCDEV  
MCUSED  
=
=
Number of macrocells in the device  
Total number of macrocells in the design, as reported in  
the RPT File  
fMAX  
togLC  
=
=
Highest clock frequency to the device  
Average percentage of logic cells toggling at each clock  
(typically 12.5%)  
A, B, C  
=
Constants (shown in Table 26)  
Table 26. MAX 3000A ICC Equation Constants  
Device  
A
B
C
EPM3032A  
EPM3064A  
EPM3128A  
EPM3256A  
EPM3512A  
0.71  
0.71  
0.71  
0.71  
0.71  
0.30  
0.30  
0.30  
0.30  
0.30  
0.014  
0.014  
0.014  
0.014  
0.014  
The ICCINT calculation provides an ICC estimate based on typical  
conditions using a pattern of a 16–bit, loadable, enabled, up/down  
counter in each LAB with no output load. Actual ICC should be verified  
during operation because this measurement is sensitive to the actual  
pattern in the device and the environmental operating conditions.  
Figures 12 and 13 show the typical supply current versus frequency for  
MAX 3000A devices.  
Altera Corporation  
39  