 浏览型号5M2210ZF324A5N的Datasheet PDF文件第30页浏览型号5M2210ZF324A5N的Datasheet PDF文件第31页浏览型号5M2210ZF324A5N的Datasheet PDF文件第32页浏览型号5M2210ZF324A5N的Datasheet PDF文件第33页浏览型号5M2210ZF324A5N的Datasheet PDF文件第35页浏览型号5M2210ZF324A5N的Datasheet PDF文件第36页浏览型号5M2210ZF324A5N的Datasheet PDF文件第37页浏览型号5M2210ZF324A5N的Datasheet PDF文件第38页  
2–28  
Chapter 2: MAX V Architecture  
I/O Structure  
I/O Blocks  
The IOEs are located in I/O blocks around the periphery of the MAX V device. There  
are up to seven IOEs per row I/O block and up to four IOEs per column I/O block.  
Each column or row I/O block interfaces with its adjacent LAB and MultiTrack  
interconnect to distribute signals throughout the device. The row I/O blocks drive  
row, column, or DirectLink interconnects. The column I/O blocks drive column  
interconnects.  
1
5M40Z, 5M80Z, 5M160Z, and 5M240Z devices have a maximum of five IOEs per row  
I/O block.  
Figure 2–20 shows how a row I/O block connects to the logic array.  
Figure 2–20. Row I/O Block Connection to the Interconnect (Note 1)  
R4 Interconnects  
C4 Interconnects  
I/O Block Local  
Interconnect  
data_out  
[6..0]  
7
OE  
[6..0]  
7
LAB  
Row  
I/O Block  
fast_out  
[6..0]  
7
7
data_in[6..0]  
Direct Link  
Interconnect  
from Adjacent LAB  
Direct Link  
Interconnect  
Row I/O Block  
Contains up to  
Seven IOEs  
to Adjacent LAB  
LAB Column  
clock [3..0]  
LAB Local  
Interconnect  
Note to Figure 2–20:  
(1) Each of the seven IOEs in the row I/O block can have one data_outor fast_outoutput, one OEoutput, and  
one data_ininput.  
MAX V Device Handbook  
December 2010 Altera Corporation  