Cyclone V Device Datasheet
CV-51002 | 2019.01.25
Recommended Operating Conditions
Table 4.
Recommended Operating Conditions for Cyclone V Devices
This table lists the steady-state voltage values expected from Cyclone V devices. Power supply ramps must all be strictly monotonic, without plateaus.
Symbol
Description
Condition
Minimum(2)
Typical
Maximum(2)
Unit
VCC
Core voltage, periphery circuitry power supply,
transceiver physical coding sublayer (PCS)
power supply, and transceiver PCI Express*
(PCIe*) hard IP digital power supply
Devices without internal
scrubbing feature
1.07
1.1
1.13
V
Devices with internal
1.12
1.15
1.18
V
scrubbing feature (with SC
(3)
suffix)
VCC_AUX
Auxiliary supply
—
2.375
3.135
2.85
2.5
3.3
3.0
2.5
3.3
3.0
2.5
1.8
1.5
1.35
1.25
1.2
2.625
3.465
3.15
V
V
V
V
V
V
V
V
V
V
V
(4)
VCCPD
I/O pre-driver power supply
3.3 V
3.0 V
2.5 V
3.3 V
3.0 V
2.5 V
1.8 V
1.5 V
1.35 V
1.25 V
1.2 V
2.375
3.135
2.85
2.625
3.465
3.15
VCCIO
I/O buffers power supply
2.375
1.71
2.625
1.89
1.425
1.283
1.19
1.575
1.418
1.31
1.14
1.26
V
continued...
(2)
(3)
(4)
The power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance
requirements. Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
The SEU internal scrubbing feature is available for Cyclone V E, GX, SE, and SX devices with the "SC" suffix in the part number. For
device availability and ordering, contact your local Intel sales representatives.
VCCPD must be 2.5 V when VCCIO is 2.5, 1.8, 1.5, 1.35, 1.25, or 1.2 V. VCCPD must be 3.0 V when VCCIO is 3.0 V. VCCPD must be 3.3 V
when VCCIO is 3.3 V.