AV-51002
2015.12.16
1-3
Maximum Allowed Overshoot and Undershoot Voltage
Symbol
VCCPLL_HPS
VCC_AUX_SHARED
IOUT
Description
Minimum
–0.50
–0.50
–25
Maximum
3.25
Unit
V
HPS PLL analog power supply
HPS auxiliary power supply
DC output current per pin
Operating junction temperature
Storage temperature (no bias)
3.25
V
40
mA
°C
°C
TJ
–55
125
TSTG
–65
150
Maximum Allowed Overshoot and Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in the following table and undershoot to –2.0 V for input currents less than
100 mA and periods shorter than 20 ns.
The maximum allowed overshoot duration is specified as a percentage of high time over the lifetime of the device. A DC signal is equivalent to
100% duty cycle.
For example, a signal that overshoots to 4.00 V can only be at 4.00 V for ~15% over the lifetime of the device; for a device lifetime of 10 years, this
amounts to 1.5 years.
Arria V GX, GT, SX, and ST Device Datasheet
Send Feedback
Altera Corporation