AV-51002
2015.12.16
1-14
OCT Variation after Power-Up Calibration
The definitions for the equation are as follows:
• The ROCT value calculated shows the range of OCT resistance with the variation of temperature and VCCIO
• RSCAL is the OCT resistance value at power-up.
.
• ΔT is the variation of temperature with respect to the temperature at power up.
• ΔV is the variation of voltage with respect to the VCCIO at power up.
• dR/dT is the percentage change of RSCAL with temperature.
• dR/dV is the percentage change of RSCAL with voltage.
OCT Variation after Power-Up Calibration
Table 1-10: OCT Variation after Power-Up Calibration for Arria V Devices
This table lists OCT variation with temperature and voltage after power-up calibration. The OCT variation is valid for a VCCIO range of 5% and a
temperature range of 0°C to 85°C.
Symbol
Description
VCCIO (V)
Value
0.100
0.100
0.100
0.100
0.150
0.150
0.150
0.189
0.208
0.266
0.273
0.200
0.200
0.317
Unit
3.0
2.5
1.8
dR/dV
OCT variation with voltage without recalibration
1.5
%/mV
1.35
1.25
1.2
3.0
2.5
1.8
OCT variation with temperature without
recalibration
dR/dT
1.5
%/°C
1.35
1.25
1.2
Arria V GX, GT, SX, and ST Device Datasheet