Intel StrataFlash® Wireless Memory (L18)  
Before issuing a new command, the Status Register contents should be examined and then cleared  
using the Clear Status Register command. Any valid command can follow, when word  
programming has completed.  
11.1.1  
Factory Word Programming  
Factory word programming is similar to word programming in that it uses the same commands and  
programming algorithms. However, factory word programming enhances the programming  
performance with VPP = VPPH. This can enable faster programming times during OEM  
manufacturing processes. Factory word programming is not intended for extended use. See Section  
5.2, “Operating Conditions” on page 25 for limitations when VPP = VPPH  
.
Note:  
When VPP = VPPL, the device draws programming current from the VCC supply. If VPP is driven  
by a logic signal, VPPL must remain above VPPL MIN to program the device. When VPP = VPPH  
the device draws programming current from the VPP supply. Figure 27, “Example VPP Supply  
Connections” on page 63 shows examples of device power supply configurations.  
,
11.2  
Buffered Programming  
The device features a 32-word buffer to enable optimum programming performance. For Buffered  
Programming, data is first written to an on-chip write buffer. Then the buffer data is programmed  
into the flash memory array in buffer-size increments. This can improve system programming  
performance significantly over non-buffered programming.  
When the Buffered Programming Setup command is issued (see Section 9.2, “Device Commands”  
on page 47), Status Register information is updated and reflects the availability of the write buffer.  
SR[7] indicates buffer availability: if set, the buffer is available; if cleared, the write buffer is not  
available. To retry, issue the Buffered Programming Setup command again, and re-check SR[7].  
When SR[7] is set, the buffer is ready for loading. (see Figure 41, “Buffer Program Flowchart” on  
page 87).  
On the next write, a word count is written to the device at the buffer address. This tells the device  
how many data words will be written to the buffer, up to the maximum size of the buffer.  
On the next write, a device start address is given along with the first data to be written to the flash  
memory array. Subsequent writes provide additional device addresses and data. All data addresses  
must lie within the start address plus the word count. Optimum programming performance and  
lower power usage are obtained by aligning the starting address at the beginning of a 32-word  
boundary (A[4:0] = 0x00). Crossing a 32-word boundary during programming will double the total  
programming time.  
After the last data is written to the buffer, the Buffered Programming Confirm command must be  
issued to the original block address. The WSM begins to program buffer contents to the flash  
memory array. If a command other than the Buffered Programming Confirm command is written to  
the device, a command sequence error occurs and Status Register bits SR[7,5,4] are set. If an error  
occurs while writing to the array, the device stops programming, and Status Register bits SR[7,4]  
are set, indicating a programming failure.  
Reading from another partition is allowed while data is being programmed into the array from the  
write buffer (see Section 14.0, “Dual-Operation Considerations” on page 71).  