IN74HC652
AC ELECTRICAL CHARACTERISTICS(CL=50pF,Input tr=tf=6.0 ns)
VCC
V
Guaranteed Limit
Symbol
Parameter
Unit
25 °C ≤85°C ≤125
to
-55°C
180
36
°C
tPLH
,
Maximum Propagation Delay, Input A to 2.0
Output B (or Input B to Output A) 4.5
225
45
270
54
ns
ns
tPHL
(Figures 2,3 and 9)
6.0
31
38
46
tPLH
,
Maximum Propagation Delay, A-to-B 2.0
Clock to Output B (or B-to-A Clock to 4.5
240
48
300
60
360
72
tPHL
Output
A) 6.0
41
51
61
(Figures 1 and 9)
tPLH
,
Maximum Propagation Delay, A-to-B 2.0
Source to Output B (or B-to-A Source to 4.5
220
44
275
55
330
66
ns
ns
ns
ns
tPHL
Output A) (Figures 4 and 9)
6.0
37
47
56
tPLZ
,
Maximum Propagation Delay , Direction 2.0
or Output Enable to Output A or B 4.5
170
34
215
43
255
51
tPHZ
(Figures 5,6 and 10)
6.0
29
37
43
tPZL
,
Maximum Propagation Delay , Direction 2.0
or Output Enable to Output A or B 4.5
180
36
225
45
270
54
tPZH
(Figures 5,6 and 10)
6.0
31
38
46
tTLH, tTHL Maximum Output Transition Time, Any 2.0
60
75
90
Output
4.5
6.0
-
12
15
18
(Figure 2)
10
13
15
CIN
COUT
Maximum Input Capacitance
Maximum Three-State I/O Capacitance
(Output in High-Impedance State
10
10
10
pF
pF
-
15
15
15
Power Dissipation Capacitance (Per
Channel)
Typical @25°C,VCC=5.0 V
CPD
Used to determine the no-load dynamic
60
pF
power
consumption:
PD=CPDVCC2f+ICCVCC
4