IN74AC164
DC ELECTRICAL CHARACTERISTICS(Voltages Referenced to GND)
VCC
Guaranteed
Limits
25 °C -40°C to
85°C
Symbol
VIH
Parameter
Test Conditions
V
Unit
V
Minimum
Level
High- VOUT=0.1 V or VCC-0.1 V 3.0
2.1
3.15
3.85
0.9
2.1
3.15
3.85
0.9
Input
4.5
5.5
Voltage
VIL
Maximum Low - VOUT=0.1 V or VCC-0.1 V 3.0
V
V
Level
Input
4.5
5.5
3.0
4.5
5.5
1.35
1.65
2.9
1.35
1.65
2.9
Voltage
Minimum
Level
VOH
High-
I
OUT ≤ -50 µA
Output
4.4
4.4
Voltage
5.4
5.4
*VIN=VIH
IOH=-12
or
or
VIL
mA 3.0
mA 4.5
5.5
2.56
3.86
4.86
0.1
2.46
3.76
4.76
0.1
IOH=-24
IOH=-24 mA
OUT ≤ 50 µA
VOL
Maximum
Level
Low-
3.0
V
I
Output
4.5
0.1
0.1
Voltage
5.5
0.1
0.1
*VIN=VIH
IOL=12
VIL
mA 3.0
mA 4.5
5.5
0.36
0.36
0.36
0.44
0.44
0.44
IOL=24
IOL=24 mA
IIN
Maximum Input VIN=VCC or GND
Leakage Current
5.5
±0.1
±1.0
µA
IOLD
+Minimum
V
OLD=1.65 V Max
5.5
5.5
5.5
75
mA
Dynamic Output
Current
IOHD
+Minimum
V
OHD=3.85 V Min
-75
40
mA
Dynamic Output
Current
ICC
Maximum
VIN=VCC or GND
4.0
µA
Quiescent Supply
Current
(per Package)
* All outputs loaded; thresholds on input associated with output under test.
+Maximum test duration 2.0 ms, one output loaded at a time.
Note: IIN and ICC @ 3.0 V are guaranteed to be less than or equal to the respective limit @ 5.5 V
VCC
3