IN5851
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
DC Supply Voltage (Referenced to GND)
DC Input Voltage (Referenced to GND)
Operating Temperature
Min
2.0
0
Max
6.0
VCC
+70
Unit
V
V
VCC
VIN
TA
-20
°C
This device contains protection circuitry to guard against damage due to high static voltages or electric
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated
voltages to this high-impedance circuit. For proper operation, VIN and VOUT should be constrained to the range
GND≤(VIN or VOUT)≤VCC.
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC).
Unused outputs must be left open.
DC ELECTRICAL CHARACTERISTICS
(Voltages Referenced to GND, VCC = 2.0 V to 6.0V,
TA = -20 to +70°C, FOSC=2.4KHz)
Guaranteed Limits
Symbol
VIH
VIL
Parameter
Input High Voltage
Input Low Voltage
Test Conditions
Min
0.8VCC
0
Typ
Max
VCC
0.2VCC
Unit
V
V
VDR
Minimum Memory
Retention Voltage
1.0
V
IOL
Output Leakage Current
VCC=6.0V
,
1
µA
MUTE,PULSE=6.0V
IOL1
Minimum Output current VO=0.8V,VCC=2.5V
0.5
mA
______
(MUTE,PULSE)
IOL2
Minimum Output current VO=0.8V,VCC=3.5V
1.7
mA
______
(MUTE,PULSE)
IOD
ISD
Operating Current
All output under no load,
VCC=2.0V
VCC=2.5V
VIH=2.5V
150
1
µA
µA
µA
Maximum Standby
Current
Minimum Reference
Current
IREF
VCC=6.0V
1
5