IL79XXC SERIES
IL7905
Electrical characteristics
(VI = -10V, Io = 500mA, 0°C <TJ<+125°C unless otherwise noted)
Characteristic
Symbol
Min
Typ
Max
Unit
Vo
Regline
-4.8
-5.0
-5.2
Vdc
mV
Output Voltage (TJ=+25°C)
Line Regulation (Note 1)
(TJ=+25°C, Io = 100mA)
-7.0Vdc ≥ VI ≥ -25Vdc
-8.0Vdc ≥ VI ≥ -12Vdc
-
-
7.0
2.0
50
25
(TJ=+25°C, Io =500mA)
-7.0Vdc ≥ VI ≥ -25Vdc
-8.0Vdc ≥ VI ≥ -12Vdc
-
-
35
100
50
8.0
Regload
Vo
mV
Load Regulation (TJ=+25°C, Note 1)
5.0mA ≤ Io ≤ 1.5A
-
-
11
100
50
-5.25
4.0
250mA ≤ Io ≤ 750 mA
Output Voltage
-4.75
-
Vcd
5.0mA ≤ Io ≤ 1.0A, Po ≤15 W
-7.0Vdc ≥ VI ≥ -25Vdc
IIB
∆ IIB
-
4.3
8.0
mA
mA
Input Bias Current (TJ=+25°C)
Input Bias Current Change
-7.0Vdc ≥ VI ≥ -25Vdc
-
-
-
-
-
40
1.3
0.5
-
5.0mA ≤ Io ≤ 1.0A
eon
Output Noise Voltage (TA=+25°C)
10 Hz ≤ f ≤ 100 kHz
µV
Ripple Rejection (Io=20mA f=120Hz)
Dropout Voltage (Io=1.0A, TJ =+25°C)
Average Temperature Coefficient of
Output Voltage Io=5.0mA, 0°C <TJ<+125°C
RR
-
-
-
70
2.0
-1.0
-
-
-
dB
Vdc
mV/°C
VI-Vo
DVo/DT
IL7905.2
Electrical characteristics
(VI = -10V, Io = 500mA, 0°C <TJ<+125°C unless otherwise noted)
Characteristic
Symbol
Min
Typ
Max
Unit
Vo
Regline
-5.0
-5.2
-5.4
Vdc
mV
Output Voltage (TJ=+25°C)
Line Regulation (Note 1)
(TJ=+25°C, Io = 100mA)
-7.2Vdc ≥ VI ≥ -25Vdc
-8.0Vdc ≥ VI ≥ -12Vdc
-
-
8.0
2.2
52
27
(TJ=+25°C, Io =500mA)
-7.2Vdc ≥ VI ≥ -25Vdc
-8.0Vdc ≥ VI ≥ -12Vdc
-
-
37
105
52
8.5
Regload
Vo
mV
Load Regulation (TJ=+25°C, Note 1)
5.0mA ≤ Io ≤ 1.5A
-
-
12
105
52
-5.45
4.5
250mA ≤ Io ≤ 750 mA
Output Voltage
-4.95
-
Vcd
5.0mA ≤ Io ≤ 1.0A, Po ≤15 W
-7.2Vdc ≥ VI ≥ -20Vdc
IIB
∆ IIB
-
4.3
8.0
mA
mA
Input Bias Current (TJ=+25°C)
Input Bias Current Change
-7.2Vdc ≥ VI ≥ -25Vdc
-
-
-
-
-
42
1.3
0.5
-
5.0mA ≤ Io ≤ 1.5A
eon
Output Noise Voltage (TA=+25°C)
10 Hz ≤ f ≤ 100 kHz
µV
Ripple Rejection (Io=20mA f=120Hz)
Dropout Voltage (Io=1.0A, TJ =+25°C)
Average Temperature Coefficient of
Output Voltage Io=5.0mA, 0°C <TJ<+125°C
Note:
RR
-
-
-
68
2.0
-1.0
-
-
-
dB
Vdc
mV/°C
VI-Vo
DVo/Vo
1. Load and line regulation are specified at constant junction temperature. Changes in Vo due to heating effects must be taken into
account separately .Pulse testing with low duty cycle is used.
2