 浏览型号IA8344-PLC44I-01的Datasheet PDF文件第31页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第32页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第33页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第34页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第36页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第37页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第38页浏览型号IA8344-PLC44I-01的Datasheet PDF文件第39页  
IA8044/IA8344  
SDLC COMMUNICATIONS CONTROLLER  
Data Sheet  
Frame Format Options  
The various frame formats available with the IA8044/IA8344 are the standard SDLC format, the no  
control field format, the no control field and no address field format and the no FCS field format.  
The standard SDLC format consists of an opening flag, an 8-bit address field, an 8-bit control field,  
and n-byte information field, a 16-bit frame check sequence field and a closing flag. The FCS is  
generated by the CCIT-CRC polynomial (X16 +X12 + X5 + 1). The FCS is calculated on the  
address, control and information fields. The address and control fields may not be extended. The  
address is contained in STAD and the control filed is contained in either RCB or TCB. This format  
is supported by both AUTO and FLEXIBLE modes.  
The no control field format is only supported by the FLEXIBLE mode. In this format TCB and  
RCB are not used and the information field starts immediately after the address field. A control  
field may still be used in the frame but the SIU will treat it as a byte of the information field.  
The no control field and no address field format is only supported by the FLEXIBLE mode. In this  
format STAD, TCB and RCB are not used and the information field starts immediately after the  
opening flag. This option can only be used with the no control field option. Again a control field  
and address field may still be used in the frame but the SIU will treat each as a byte of the  
information field.  
The no FCS field format prevents an FCS from being generated during transmission or being  
checked during reception. This option may be used in conjunction with the other frame format  
options. This option will work with both FLEXIBLE and AUTO modes. In AUTO mode it could  
cause protocol violations. An FCS field may still be used in the frame but the SIU will treat it as a  
byte of the information field.  
All the possible Frame Format combinations are shown in the table below along with the bit settings  
that select a given format.  