 浏览型号IA82527PLC44AR2的Datasheet PDF文件第50页浏览型号IA82527PLC44AR2的Datasheet PDF文件第51页浏览型号IA82527PLC44AR2的Datasheet PDF文件第52页浏览型号IA82527PLC44AR2的Datasheet PDF文件第53页浏览型号IA82527PLC44AR2的Datasheet PDF文件第54页浏览型号IA82527PLC44AR2的Datasheet PDF文件第56页浏览型号IA82527PLC44AR2的Datasheet PDF文件第57页浏览型号IA82527PLC44AR2的Datasheet PDF文件第58页  
IA82527  
Data Sheet  
CAN Serial Communications Controller  
December 20, 2012  
Errata No. 2  
Problem: Setting the IntPnd bit to 1 from CPU interface will not cause Interrupt.  
Description: During normal operation, a CAN message event sets the IntPnd bit of Control 0  
Register of the appropriate message box (assuming appropriate interrupt enables are set), and the  
interrupt signal is asserted. The CPU will then reset IntPnd to clear the interrupt. The errata  
issue occurs if the user directly sets the IntPnd bit via the CPU interface, no interrupt will be  
generated.  
Workaround: None.  
Errata No. 3  
Problem: An unintended Remote Frame may be generated.  
Description: If a Message Box is set to receive and a Remote Frame with a matching ID and  
Data Length Code (DLC) is received, the IA82527 will generate an unexpected Remote Frame  
for the ID in the Message Box instead of just acknowledging the CAN message.  
A Message Box configured as follows may lead to this scenario, as explained below:  
1. A Message Box is set with an ID in the Arbitration Registers to match the ID of Remote  
Frame.  
2. The Message Box Control_0 Register has MsgVal(Bits[7-6]) in the set state.  
3. The Message Box Control_1 Register has all fields in the reset state.  
4. The Message Box Configuration Register has the Dir bit (bit 3) reset to 0 for receive.  
5. The Message Box Configuration Register has the DLC field set to match the DLC of the  
Remote Frame.  
When the IA82527 sees a Remote Frame that matches the Message Box ID and DLC, the  
IA82527 will generate the expected RX_OK status change interrupt. The IA82527 will also  
generate an unexpected RX interrupt for the Message Box that matches the ID of the Remote  
Frame if the RXIE field of the Message Box Control_0 register is in the set state. In addition,  
the IA82527 will generate an unexpected Remote Frame for the ID in the Message Box.  
Workaround: In a system that uses remote frames, only use a single Remote Frame Requester  
for a single Remote Frame Responder.  