IA186XL/IA188XL
16-Bit Microcontrollers
Data Sheet
July 6, 2011
5.6
Ready, Peripheral and Queue Status Timings
TA = -40○C to +85○C, VCC = 5V + 10%
All timings are measured at 1.5V and 50 pF loading on CLKOUT unless otherwise noted.
All output test conditions are with CL = 50 pF.
For AC tests, input VIL = 0.45V and VIH = 2.4V except at X1 where VIH = VCC – 0.5V.
Table 18. Ready, Peripheral and Queue Status Timings
Values
Test
Conditions
Symbol
Parameter
Unit
Min
8
Max
Synchronous Ready (SRDY)
Transition Setup Time(1)
TSRYCL
TCLSRY
TARYCH
ns
ns
ns
SRDY Transition Hold Time(1)
8
ARDY Resolution Transition Setup
Time(2)
8
TCLARX
ARDY Active Hold Time(1)
ARDY Inactive Holding Time
8
8
ns
ns
TARYCHL
Asynchronous Ready (ARDY) Setup
Time(1)
INTx, NMI, TEST, BUSY, TMR IN
Setup Time(2)
TARYLCL
TINVCH
10
ns
ns
8
8
TINVCL
TCLTMV
TCHQSV
DRQ0, DRQ1 Setup Time(2)
Timer Output Delay
ns
ns
ns
17
22
Queue Status Delay
NOTES:
1. To guarantee proper operation.
2. To guarantee recognition at clock edge.
®
IA211080711-09
UNCONTROLLED WHEN PRINTED OR COPIED
http://www.Innovasic.com
Customer Support:
Page 56 of 75
1-888-824-4184