 浏览型号AM186ES-33VIW的Datasheet PDF文件第146页浏览型号AM186ES-33VIW的Datasheet PDF文件第147页浏览型号AM186ES-33VIW的Datasheet PDF文件第148页浏览型号AM186ES-33VIW的Datasheet PDF文件第149页浏览型号AM186ES-33VIW的Datasheet PDF文件第151页浏览型号AM186ES-33VIW的Datasheet PDF文件第152页浏览型号AM186ES-33VIW的Datasheet PDF文件第153页浏览型号AM186ES-33VIW的Datasheet PDF文件第154页  
IA186ES/IA188ES  
Data Sheet  
8-Bit/16-Bit Microcontrollers  
November 15, 2011  
9.  
Errata  
The following errata are associated with Version 03 of the IA186ES/IA188ES. A workaround to  
the identified problem has been provided where possible.  
9.1  
Errata Summary  
Table 92 presents a summary of errata.  
Table 92. Summary of Errata  
Errata  
No.  
Problem  
Ver. 03  
Exists  
1
There is a difference in how priority of timer interrupts are asserted between the  
original AMD part and the Innovasic part.  
2
3
4
5
6
7
Lock up just after reset is released.  
Exists  
Exists  
Exists  
Exists  
Exists  
Exists  
Intermittent startup.  
Timer Operation in continuous mode.  
DMA interrupt will not bring device out of halt state.  
Does not clear the interrupt req bit for INT0 upon entering the ISR.  
There is a difference in how hardware handshaking for UARTs during a bus hold  
cycle is handled between the original AMD part and the Innovasic part.  
9.2  
Errata Detail  
Errata No. 1  
Problem: There is a difference in how priority of timer interrupts are asserted between the  
original AMD part and the Innovasic part.  
Description: In the original AMD part, timer interrupts cannot be interrupted by another timer  
interrupt, even if the new timer interrupt is of a higher priority. The Innovasic part will interrupt  
a timer interrupt with a higher-priority timer interrupt. Additionally, if a lower-priority timer  
interrupt is interrupted with a higher-priority timer interrupt and another incident of the lower-  
priority interrupt occurs during the processing of the higher-priority interrupt, upon execution of  
the EOI, a new lower-priority interrupt will be initiated, possibly orphaning the original lower-  
priority timer interrupt.  
®