SAB 82525
SAB 82526
SAF 82525
SAF 82526
Strobe Timing (Clock Mode1)
RxCLK
t RSH
tRSD
tRSS
AxCLK
tXSD
tXSH
t XSS
TxCLK
tXCZ
t XDD
tSDD
tXSZ
TxD
TxD
tXCZ
t XDD
Bus
Timing
Mode 2
ITT00961
Parameter
Limit Values
max.
Symbol
min.
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Receive strobe delay
Receive strobe setup
Receive strobe hold
Transmit strobe delay
Transmit strobe setup
Transmit strobe hold
Transmit data delay
tRSD
tRSS
tRSH
tXSD
tXSS
tXSH
tXDD
tSDD
tXCZ
tXSZ
30
60
30
30
60
30
68
90
50
50
Strobe data delay
High impedance from clock
High impedance from strobe
Semiconductor Group
115