Operational Description  
4.7.2.2 Single-Channel Loop-Backs  
Single-channel loop-backs are always performed directly in the IEC-Q. No difference  
between the B1-channel and the B2-channel loop-back control procedure exists. They  
are therefore discussed together.  
In EOC Auto mode the B1-channel is closed with the EOC-command LB1. LB2 causes  
the channel B2 to be looped back. Because these functions are latched, both channels  
may be looped back simultaneously by sending first the command to close one channel  
followed by the command for the second one.  
In the EOC Transparent mode, single channels are closed with the corresponding  
MON-8-commands.  
Single-channel loop-backs are resolved in the same manner as described for the  
complete loop-back. The NT may be deactivated with layer 2 while single loop-backs are  
closed.  
4.7.2.3 Repeater Loop-Back (No. 1A)  
Loop-back #1A is always closed in the repeater. Functionally it corresponds to  
loop-backs #1 and #3 on the exchange and on the network side. If a line contains more  
than one repeater unit, it is possible to address each unit individually in order to close  
loop-back #1A in the specified unit only.  
For loop-back #1A everything described in section "Analog Loop-Back (No. 1/No. 3)",  
page 187 applies: The loop-back is opened with the C/I-command RES, closed with the  
C/I-command ARL, and it is closed as near to the U-interface as possible. The difference  
results from the fact that the command ARL needs to be generated by the repeater  
control unit (µP or ASIC) according to national repeater specifications.  
This specification defines an EOC-command which will activate loop-back #1A if  
received in conjunction with the repeater address (001B). The NT-RP is operating in  
transparent mode. The repeater control unit watches for MON-0-commands with  
address (001B). If the predefined loop-back #1A command is received, the repeater  
control unit sends the C/I-code ARL to the LT-RP and loop-back #1A will be closed.  
For more information, see "EOC Addressing Management", page 257.  
Figure 82 illustrates this in a system with two repeater units where the second unit is  
requested to close loop-back #1A.  