Functional Description  
Table 10  
Q.921  
Management Entity Actions for MDL Error Indications (cont’d)  
Error Type  
Error  
Code  
Error  
Condition  
Affected  
States  
Network  
Management Management  
User  
Action  
Action  
J
N(R) Error  
7, 8  
7, 8  
Error log  
Dependent on  
implementation  
K
Receipt of  
FRMR  
Error log  
Dependent on  
implementation  
response  
L
Receipt of non- 4, 5, 6, 7, 8 Error log  
implemented  
frame  
Dependent on  
implementation  
Other  
M (see Receipt of I-field 4, 5, 6, 7, 8 Error log  
Dependent on  
implementation  
Note 2)  
not permitted  
N
Receipt of  
frame with  
wrong size  
4, 5, 6, 7, 8 Error log  
4, 5, 6, 7, 8 Error log  
Dependent on  
implementation  
O
N201 Error  
Dependent on  
implementation  
Note 1: For the description of the affected states see Annex B.  
Note 2: According to Q.921 § 5.8.5 this error code will never be generated.  
Reactions of the ISAC-S and Necessary Software Reactions  
As the auto- mode is only to be used in states 7, 8 and as it has to be switched to non-auto  
mode where in states 1-6, we do not have to deal with error code G and H.  
A) The ISAC-S does not react at all (our implementation). The software is not informed, as  
no action is mandatory according to Q.921.  
B) see 4.2a)  
C) "  
D) "  
E) "  
F) "  
I) see further Criteria Leading to a Reestablishment  
J) see Frame Rejection Condition  
K) see further Criteria Leading to a Reestablishment  
L) see Frame Rejection Condition  
M)  
N) see Frame Rejection Condition  
O) only internal software timer, no device action.  
Conclusion:  
For your error-processing with ISAC-S we suggest to implement the software design shown in  
the following figures 60 through 64 into your interrupt service routine.  