PROFET + 24V  
BTT6200-4ESA  
Diagnostic functions  
7.3.2  
SENSE signal timing  
Figure 23 shows the timing during settling and disabling of the SENSE.  
VINx  
t
ILx  
tONx  
tOFFx  
tONx  
90% of  
IL static  
t
VDEN  
t
IIS  
tsIS(LC)  
tsIS(chC)  
tsIS(OFF)  
tsIS(ON)  
tsIS(ON_DEN)  
90% of  
IIS static  
t
t
VDSEL  
VINy  
t
ILy  
tONy  
t
current sense settling disabling time.vsd  
Figure 23  
Current sense settling / disabling timing  
7.3.3  
SENSE signal in open load  
7.3.3.1  
Open load in ON diagnostic  
If the channel is ON, a leakage current can still flow through an open load, for example due to humidity. The  
parameter IL(OL) gives the threshold of recognition for this leakage current. If the current IL flowing out the  
power DMOS is below this value, the device recognizes a failure, if the DEN (and DSEL) is selected. In that case,  
the SENSE current is below IIS(OL). Otherwise, the minimum SENSE current is given above parameter IIS(OL)  
.
Figure 24 shows the SENSE current behavior in this area. The red curve shows a typical product curve. The blue  
curve shows the ideal current sense.  