BTS7040-1EPA
PROFET™ +2 12V
Power Supply
6.3
Electrical Characteristics Power Supply
VS = 6 V to 18 V, TJ = -40 °C to +150 °C
Typical values: VS = 13.5 V, TJ = 25 °C
Typical resistive load connected to the output for testing (unless otherwise specified):
RL = 3.3 Ω
Table 9
Electrical Characteristics: Power Supply - General
Parameter
Symbol
Values
Typ.
Unit Note or
Test Condition
Number
Min.
Max.
VS pin
Power Supply Undervoltage VS(UV)
Shutdown
1.8
2.3
3.0
3.1
V
VS decreasing
IN = “high”
From VDS ≤ 0.5 V to
P_6.4.0.1
V
DS = VS
See Figure 14
Power Supply Minimum
Operating Voltage
VS(OP)
2.0
4.1
V
VS increasing
IN = “high”
P_6.4.0.3
From VDS = VS to
V
DS ≤ 0.5 V
See Figure 14
1)
Power Supply Undervoltage VS(HYS)
Shutdown Hysteresis
–
0.7
5
–
V
P_6.4.0.6
P_6.4.0.7
P_6.4.0.9
VS(OP) - VS(UV)
See Figure 14
Power Supply Undervoltage tDELAY(UV)
Recovery Time
2.5
16
7.5
30
ms
V
dVS/dt ≤ 0.5 V/µs
VS ≥ -1 V
See Figure 14
1)
Breakdown Voltage
between GND and VS Pins in
Reverse Battery
-VS(REV)
–
IGND(REV) = 7 mA
TJ = 150 °C
1) Not subject to production test - specified by design.