BTS7012-2EPA  
PROFET™ +2 12V  
Power Stages  
7.2.3  
Output Voltage Limitation  
To increase the current sense accuracy, VDS voltage is monitored. When the output current IL decreases while  
the channel is diagnosed (DEN pin set to “high”, channel selected with DSEL pins - see Figure 18) bringing VDS  
equal or lower than VDS(SLC), the output DMOS gate is partially discharged. This increases the output resistance  
so that VDS = VDS(SLC) even for very small output currents. The VDS increase allows the current sensing circuitry  
to work more efficiently, providing better kILIS accuracy for output current in the low range.  
IN  
t
DEN  
tsIS(ON)  
tsIS(OFF)  
t
IL  
t
VDS  
VS  
VDS(SLC)  
t
PowerStage_GBR_diag.emf  
Figure 18 Output Voltage Limitation activation during diagnosis  
7.3  
Advanced Switching Characteristics  
7.3.1  
Inverse Current behavior  
When VOUT > VS, a current IINV flows into the power output transistor (see Figure 19). This condition is known  
as “Inverse Current”.  
If the channel is in OFF state, the current flows through the intrinsic body diode generating high power losses  
therefore an increase of overall device temperature. This may lead to a switch OFF of unaffected channels due  
to Overtemperature. If the channel is in ON state, RDS(INV) can be expected and power dissipation in the output  
stage is comparable to normal operation in RDS(ON)  
.
During Inverse Current condition, the channel remains in ON or OFF state as long as IINV < IL(INV). If one channel  
has inverse current applied, the neighbor channel is not influenced, meaning that switching ON and OFF  
timings, protection (Overcurrent, Overtemperature) and current sensing (kILIS) are still within specified limits.  
With InverseON, it is possible to switch ON the channel during Inverse Current condition as long as IINV < IL(INV)  
(see Figure 20).  
Data Sheet  
23  
Rev. 1.10  
2020-12-14  