BAS19...BAS21
Electrical Characteristics
at
T
A
= 25°C, unless otherwise specified
Parameter
DC Characteristics
Breakdown voltage
I
(BR)
= 100 µA, BAS19
I
(BR)
= 100 µA, BAS20
I
(BR)
= 100 µA, BAS21
Reverse current
V
R
=
V
Rmax
V
R
=
V
Rmax
,
T
A
= 150 °C
Forward voltage
I
F
= 100 mA
I
F
= 200 mA
AC Characteristics
Diode capacitance-
V
R
= 0 V,
f
= 1 MHz
Reverse recovery time
I
F
= 30 mA,
I
R
= 30 mA, measured at
I
R
= 3 mA,
t
rr
-
-
50
ns
C
T
-
-
5
pF
Symbol
min.
V
(BR)
120
200
250
I
R
-
-
V
F
-
-
Values
typ.
max.
Unit
V
-
-
-
-
-
-
-
-
-
-
µA
0.1
100
V
1
1.25
Test circuit for reverse recovery time
EHN00018
2
Aug-06-2001
Ι
F
Oscillograph
Oscillograph:
R
= 50
,
t
r
= 0.35 ns,
C
D.U.T.
R
L
= 100
Pulse generator:
t
p
= 1 s,
D
= 0.05,
t
r
= 0.6 ns,
R
i
= 50
1 pF