IMP5111/5112
IMP5218
Recommended Operating Conditions2
Parameter
Symbol
Min
Typ
Max
Units
Termpwr Voltage
VTERM
3.5
5.5
VTERM
0.8
V
High Level Disable Input Voltage
Low Level Disable Input Voltage
Operating Junction Temperature Range
VIH
2
V
VIL
0
V
0
125
°C
5218_t02.eps
Note:
2. Recommended operating conditions indicate the range over which the device is functional.
Electrical Characteristics
Unless otherwise specified, these specifications apply at an ambient operating temperature of TA = 25°C. TermPwr = 4.75V. Low duty cycle
pulse testing techniques are used which maintain junction and case temperatures equal to the ambient temperature.
Parameter
Symbol Conditions
Min
Typ
Max Units
Output High Voltage
VOUT
2.65
2.85
V
TermPwr Supply Current
ICC
All data lines = Open
6
9
mA
All data lines = 0.5V
215
375
–23
90
225
mA
µA
DISCONNECT Pins 1, 2 = 0V
VOUT = 0.5V
Output Current
IOUT
IIN
–21
–24
mA
µA
Disable Input Current
DISCONNECT Pins 1, 2 = 4.75V
DISCONNECT Pins 1, 2 = 0V
DISCONNECT Pins = 0V, VO = 0.5V
VOUT = 0V, Frequency = 1MHz
–10
10
µA
nA
Output Leakage Current
IOL
COUT
BW
Capacitance in Disabled Mode
Channel Bandwidth
3
pF
35
MHz
Termination Sink Current, per Channel
ISINK
V
OUT = 4V
60
mA
5218_t03.eps
Daily Silver IMP
Data Communications
3